Inhibitory Effect of Nasal Intermittent Positive Pressure Ventilation on Gastroesophageal Reflux

نویسندگان

  • Danny Cantin
  • Djamal Djeddi
  • Vincent Carrière
  • Nathalie Samson
  • Stéphanie Nault
  • Wan Lu Jia
  • Jennifer Beck
  • Jean-Paul Praud
  • Olivier Baud
چکیده

Non-invasive intermittent positive pressure ventilation can lead to esophageal insufflations and in turn to gastric distension. The fact that the latter induces transient relaxation of the lower esophageal sphincter implies that it may increase gastroesophageal refluxes. We previously reported that nasal Pressure Support Ventilation (nPSV), contrary to nasal Neurally-Adjusted Ventilatory Assist (nNAVA), triggers active inspiratory laryngeal closure. This suggests that esophageal insufflations are more frequent in nPSV than in nNAVA. The objectives of the present study were to test the hypotheses that: i) gastroesophageal refluxes are increased during nPSV compared to both control condition and nNAVA; ii) esophageal insufflations occur more frequently during nPSV than nNAVA. Polysomnographic recordings and esophageal multichannel intraluminal impedance pHmetry were performed in nine chronically instrumented newborn lambs to study gastroesophageal refluxes, esophageal insufflations, states of alertness, laryngeal closure and respiration. Recordings were repeated without sedation in control condition, nPSV (15/4 cmH2O) and nNAVA (~ 15/4 cmH2O). The number of gastroesophageal refluxes recorded over six hours, expressed as median (interquartile range), decreased during both nPSV (1 (0, 3)) and nNAVA [1 (0, 3)] compared to control condition (5 (3, 10)), (p < 0.05). Meanwhile, the esophageal insufflation index did not differ between nPSV (40 (11, 61) h-1) and nNAVA (10 (9, 56) h-1) (p = 0.8). In conclusion, nPSV and nNAVA similarly inhibit gastroesophageal refluxes in healthy newborn lambs at pressures that do not lead to gastric distension. In addition, the occurrence of esophageal insufflations is not significantly different between nPSV and nNAVA. The strong inhibitory effect of nIPPV on gastroesophageal refluxes appears identical to that reported with nasal continuous positive airway pressure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome

Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....

متن کامل

Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration

Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...

متن کامل

Does mechanical ventilation precipitate gastro-oesophageal reflux during enteral feeding?

The influence of intermittent positive pressure ventilation on gastro-oesophageal reflux in preterm infants is not known. In many neonatal units, however, concern that ventilation may increase gastro-oesophageal reflux (and therefore aspiration) leads to avoidance of enteral feeding during ventilation. We have therefore performed a crossover study of gastrooesophageal reflux by monitoring lower...

متن کامل

Early Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial

Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...

متن کامل

Domiciliary nasal intermittent positive pressure ventilation in severe COPD: effects on lung function and quality of life.

The aim of this study was to determine the effect of domiciliary nasal intermittent positive pressure ventilation (NIPPV) on lung function and quality of life in hypercapnic patients with chronic obstructive pulmonary disease (COPD). Fourteen hypercapnic COPD patients in a stable clinical condition were evaluated in a prospective study of domiciliary NIPPV plus long-term oxygen therapy. Baselin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016