Lymph node imaging using novel simultaneous PET/MRI and dual-modality imaging agent

نویسندگان

  • Guen Bae Ko
  • Jae Sung Lee
  • Hyun Suk Yoon
  • Daehong Kim
  • Kyeong Yun Kim
  • Min Sun Lee
  • Bo Yeun Yang
  • Jae Min Jeong
  • Dong Soo Lee
  • In Chan Song
  • Seok-ki Kim
چکیده

Seoul National University, Korea Lymph node (LN) imaging has clinical significance because the invasion status of the LN is crucial information for disease stratification, staging, and management. Compared with conventional method, simultaneous PET/MRI using the multi-modal imaging marker can offer synergistic advantages. Here, we present LN mapping using selfdeveloped PET/MRI and novel bimodal biomarker. The SiPM-based PET insert which has peak sensitivity of 3.4% and center volumetric resolution of 0.57 cubic mm was developed. The PET insert was placed between the RF and gradient coil of Bruker 7T MRI. For LN targeting, 64Cu-NOTA-ironoxide-mannose, a new LN targeted dualmodality probe yielding superior T2 contrast was used. The relaxivity of the probe was measured by phantom study. Before the simultaneous imaging, MRI of the left and right popliteal lymph node of an anaesthetized BALB/c mouse was acquired as the control. 10 μL of the tracer was then injected into the left hindpaw of same mouse. Simultaneous PET/MRI was acquired for 10 minutes after 10-min and 120-min uptake period. The r2 of the probe was 845.3 at 7T magnetic field. The simultaneous PET/ MRI has sufficient resolution and sensitivity to imaging tiny organ like mouse LN. A left popliteal LN in the 120-min post-injection MRI resulted in a remarkable signal decrease compared to those in the pre-injection MRI and that was good agreement with PET. The 10-min post-injection PET also showed clear regional activity in the LN, but the 10-min uptake period was not sufficient to generate MR contrast. It is due to the large difference in the sensitivities of the two modality. The simultaneous PET/ MRI is useful for in vivo imaging and bimodal imaging probe development particularly to generating negative T2 contrast.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

Molecular Imaging Using PET/MRI Particle

With the remarkable progress of non-invasive molecular imaging techniques, the nanotechnology could provide powerful tools for development of diagnostic and therapeutic agents in bio-and nano-medicine field. Several imaging techniques including PET and MRI system have been developed for diagnosis, providing functional and anatomical information. Recently, the combined system of PET/MRI imaging ...

متن کامل

A Dual PET / MR Imaging Nanoprobe : 124 I Labeled Gd 3 N @ C 80

The current report describes the development of a dual modality tomographic agent for both positron emission tomography and magnetic resonance imaging (PET/MRI). The dual-modality agent in this study was based on a I (PET) radiolabeled tri-gadolinium endohedral metallofullerene Gd3N@C80 (MRI) nanoprobe platform. The outer surface of the fullerene cage of the Gd3N@C80 metallofullerenes was surfa...

متن کامل

Generalized lymph node activation after Influenza vaccination on 18F FDG-PET/CT imaging, an important pitfall in PET interpretation

We report on a 59-year-old female patient with an infected vascular graft investigated with 18F FDG-PET/CT. The first of two studies showed FDG activity in the left deltoid and ipsilateral axillary lymph nodes explained by influenza vaccination the day prior. The second 18F FDG-PET/CT showed multiple FDG-avid lymph nodes on both sides of the diaphragm without tracer accumulation at the vaccinat...

متن کامل

In Vivo Dual-Modality Fluorescence and Magnetic Resonance Imaging-Guided Lymph Node Mapping with Good Biocompatibility Manganese Oxide Nanoparticles.

Multifunctional manganese oxide nanoparticles (NPs) with impressive enhanced T₁ contrast ability show great promise in biomedical diagnosis. Herein, we developed a dual-modality imaging agent system based on polyethylene glycol (PEG)-coated manganese oxide NPs conjugated with organic dye (Cy7.5), which functions as a fluorescence imaging (FI) agent as well as a magnetic resonance imaging (MRI) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015