Acoustic monitoring of intraoperative neuromuscular block.

نویسندگان

  • A Dascalu
  • E Geller
  • Y Moalem
  • M Manoah
  • S Enav
  • Z Rudick
چکیده

Standard methods for accurate intraoperative measurement of neuromuscular block are either expensive or inconvenient and are not used widely. We have evaluated a new method of monitoring neuromuscular block using a low-frequency microphone. The method is based on the phenomenon of low-frequency sound emission by contracting skeletal muscle. Acoustic monitoring (MIC) with an air-coupled microphone was used to evaluate intraoperative neuromuscular block in 25 anaesthetized patients. The MIC recorded the response of the adductor pollicis muscle to supramaximal electrical stimulation of the ulnar nerve with train-of-four stimuli. The ratios of the first response (TI) to control (TC) were used for evaluation. Data obtained from the MIC were compared with simultaneous recordings, from the same hand, of mechanomyography (FDT), electromyography (EMG) and accelerography (ACC). Throughout the operative procedure, TI/TC ratios of the acoustic method correlated with the three reference devices: FDT, 12 patients, 262 data sets, r = 0.86, bias (%MIC-%FDT) = mean -5.3 (SD 19.6)%; EMG, 18 patients, 490 data sets, r = 0.85, bias (%MIC-%EMG) = -0.39 (20.29)%; and ACC, 13 patients, 328 data sets, r = 0.91, bias (%MIC-%ACC) = -3.0 (15.6)%. We conclude that monitoring intraoperative neuromuscular block by a microphone which transduces low-frequency muscle sounds is clinically feasible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reversal of moderate and intense neuromuscular block induced by rocuronium with low doses of sugammadex for intraoperative facial nerve monitoring.

We report two cases in which moderate and intense rocuronium-induced neuromuscular block was reversed intraoperatively with low sugammadex doses in order to facilitate electromyographic evaluation of facial nerve function during surgery of the parotid gland and the middle ear. Acceleromyography was used to assess reversal of neuromuscular block before starting electromyography monitoring. Rocur...

متن کامل

Use of sugammadex in parotid surgery: a case report

BACKGROUND Parotid surgery is a common ear, nose, and throat procedure. Facial nerve paralysis is the main feared complication following this surgery. To avoid this paralysis, intraoperative facial nerve monitoring is often used, but neuromuscular blocking agents interfere with this technique. Therefore, the neuromuscular blocking agent used should have a short duration of muscle relaxation. Wi...

متن کامل

Threshold-level repetitive transcranial electrical stimulation for intraoperative monitoring of central motor conduction.

OBJECT The authors conducted a study to evaluate repetitive transcranial electrical stimulation (TES) to assess spinal cord motor tract function in individuals undergoing spine surgery, with emphasis on safety and efficacy. METHODS Somatosensory evoked potentials (SSEPs) were elicited using standard technique. Muscle electromyographic values were measured in response to a three- or four-pulse...

متن کامل

Intraoperative spinal cord monitoring for intramedullary surgery: an essential adjunct.

Intraoperative monitoring of the functional integrity of the spinal cord during removal of intramedullary spinal cord lesions is an aid in intraoperative decision making and a primary tool for the prediction of neurological outcome. Motor evoked potential monitoring has become the neurophysiological monitoring technique of choice for that purpose. In the senior author's experience with over 130...

متن کامل

Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery

Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 83 3  شماره 

صفحات  -

تاریخ انتشار 1999