Standardization of calibration and quality control using surface enhanced laser desorption ionization-time of flight-mass spectrometry.

نویسندگان

  • Judith A P Bons
  • Douwe de Boer
  • Marja P van Dieijen-Visser
  • Will K W H Wodzig
چکیده

BACKGROUND Protein profiling by surface enhanced laser desorption ionization-time of flight-mass spectrometry (SELDI-TOF-MS) is gaining importance as a diagnostic tool for a whole range of diseases. This report describes a QC procedure, which acts prospectively by checking the calibration before starting profiling experiments. METHODS A well-defined protocol for calibration of the Protein Biosystem IIc instrument was established, using a commercial QC sample containing independent certified standards and by determination of acceptance criteria. Instrument calibration was performed externally every week with the standards provided by the manufacturer. QC was performed for the period of 5 months. RESULTS According to the acceptance criteria defined in this study, data points should be in the established range of the process mean+/-2 standard deviations for the mass-to-charge ratios (m/z values), peak intensities, signal-to-noise ratios (S/N), and peak resolutions for insulin and apomyoglobin in the QC sample. Moreover, it was demonstrated that the pipetting variability in the handling of the QC sample significantly contributed to systematic errors and that spotting of a larger volume of QC sample resulted in a better reproducibility. CONCLUSIONS Stringent quality control of the calibration part of SELDI-TOF-MS experiments prevents unreliable data acquisition from the very start.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Applications of Surface-Enhanced Laser Desorption/Ionization Time-Of-Flight (SELDI-TOF) Mass Spectrometry in Defining Salivary Proteomic Profiles

Recent advancement in mass spectrometry leads us to a new era of proteomic analysis. Human saliva can be easily collected; however, the complexity of the salivary proteome in the past prevented the use of saliva for proteomic analysis. Here we review the development of proteomic analyses for human saliva and focus on the use of a new mass spectrometric technology known as surface-enhanced laser...

متن کامل

The importance of experimental design in proteomic mass spectrometry experiments: some cautionary tales.

Proteomic expression patterns derived from mass spectrometry have been put forward as potential biomarkers for the early diagnosis of cancer and other diseases. This approach has generated much excitement and has led to a large number of new experiments and vast amounts of new data. The data, derived at great expense, can have very little value if careful attention is not paid to the experiment...

متن کامل

Application of surface-enhanced laser desorption/ionization time-of-flight mass spectrometry technology for the diagnosis of colorectal adenoma

The aim of the present study was to identify a specific biological marker for the diagnosis of colorectal adenomas through the analysis of variations in serum protein profiling in colorectal adenoma patients. The study was conducted at the Renmin Hospital of Wuhan University (Wuhan, China) between September 2011 and May 2012. Surface-enhanced laser desorption/ionization time-of-flight mass spec...

متن کامل

Enhancement of sensitivity and resolution of surface-enhanced laser desorption/ionization time-of-flight mass spectrometric records for serum peptides using time-series analysis techniques.

BACKGROUND Measurement of peptide/protein concentrations in biological samples for biomarker discovery commonly uses high-sensitivity mass spectrometers with a surface-processing procedure to concentrate the important peptides. These time-of-flight (TOF) instruments typically have low mass resolution and considerable electronic noise associated with their detectors. The net result is unnecessar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinica chimica acta; international journal of clinical chemistry

دوره 366 1-2  شماره 

صفحات  -

تاریخ انتشار 2006