Validation of pulse oximetry in commercially available normobaric hypoxic chambers (NHC) has not been previously reported. The present study examined the validity of pulse oximetry (SpO2) against direct measurements of arterial oxygen saturation (SaO2) via co-oximetry (AVOXimeter 4000) in 13 young adults age 21.3 +/- 0.6 years. Over a period of 2.5 hrs, the inspired fraction of oxygen inside a NHC (Hypoxico, Inc.) was progressively reduced from 20.9% to 11.5%. Measurements of SaO2 at baseline and at 15, 30, 60, 90, 120, and 150 min during the hypoxic exposures were compared with SpO2 estimates of oxygen saturation (Nellcor 295) using reflectance (RS-10, temporal) and transmission (D-25, finger) sensors. Regression analysis and methods for assessing agreement (bias, b; precision, p) of SaO2 with SpO2 were similar (R2 = 0.92, 0.89; b = 0.016, -0.47; p = 2.47, 3.03; RS-10 and D-25, respectively). When SaO2 < 85%, RS-10 had greater validity than D-25 (R2 = 0.73, 0.56; b = 1.38, 1.13; p = 2.72, 4.34; RS-10 and D-25, respectively). In light of these findings, caution should be exercised when monitoring individuals with pulse oximetry during desaturation episodes below 85%. When employing frequent NHC exposures, a priori validation of SpO2 utilized to assess blood oxygen status appears warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse oximetry and cardiorespiratory changes during upper gastrointestinal endoscopy in dogs

Objective- The objective of the present study was to determine the changes in heart rate, respiratory rate and arterial Oxygen saturation (SpO2) by administration of three drug combinations during upper gastrointestinal endoscopy. Design- Experimental study. Animals- 21 healthy and adults dog were randomly divided into three groups. Procedures- The IV combination of 6.5 mg/kg ketamine and 0....

متن کامل

Variability in estimating shunt from single pulse oximetry measurements.

Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precision of pulse oximeters and the non-linear relationship between virtual shunt and...

متن کامل

Pulse oximetry at the roadside: a study of pulse oximetry in immediate care.

The measurement of tissue oxygen saturation with a pulse oximeter is of proved value in the hospital setting. The development of a portable oximeter has allowed this investigation to be performed during the prehospital phase of a patient's care. Pulse oximetry was performed at the roadside in 25 patients with abnormal trauma scores and found to be of benefit in detecting and monitoring hypoxia ...

متن کامل

Acute mountain sickness: increased severity during simulated altitude compared with normobaric hypoxia.

Acute mountain sickness (AMS) strikes those in the mountains who go too high too fast. Although AMS has been long assumed to be due solely to the hypoxia of high altitude, recent evidence suggests that hypobaria may also make a significant contribution to the pathophysiology of AMS. We studied nine healthy men exposed to simulated altitude, normobaric hypoxia, and normoxic hypobaria in an envir...

متن کامل

A History of Mild Traumatic Brain Injury Affects Peripheral Pulse Oximetry during Normobaric Hypoxia

INTRODUCTION Physiological and emotional stressors increase symptoms of concussion in recently injured individuals and both forms of stress-induced symptoms in people recovering from mild traumatic brain injury (mTBI), but who are asymptomatic when not stressed or are at rest. METHODS Healthy asymptomatic adults (25.0 ± 5.1 years) with a history of mTBI (n = 36) and matched healthy controls (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of applied physiology = Revue canadienne de physiologie appliquee

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2004