The effects of wire diameter and an additional lateral wire on pin and tension-band fixation subjected to cyclic loads.

نویسندگان

  • B Neat
  • M P Kowaleski
  • A S Litsky
  • R J Boudrieau
چکیده

Despite reports of frequent complications, pin and tension- band wire remains the most common repair of simple olecranon fractures and osteotomies. A recent mechanical study found wire diameter to be the key determinant of pin and tension-band construct strength; models with 1.25-mm wire were much stronger than those with standard 1.0-mm wire exposed to single loads to failure. Additionally, fixation strength was also increased when a lateral wire was used in combination with a standard figure-of-eight wire. The purpose of the present study was to assess any advantages provided by 1.25-mm wire or an additional lateral wire over 1.0-mm wire for pin and tension-band fixation subjected to cyclic loading. Pin and tension-band fixation was applied to plastic olecranon osteotomy models with three wire configurations: 1.0-mm figure-of-eight, 1.25-mm figure-of-eight, and combined 1.0-mm figure-of-eight and lateral. Cyclic load was applied while caudal osteotomy displacement was measured with an extensometer. The three groups were compared in terms of cycles to failure, mean minimum displacement, mean maximum displacement, and mean displacement per cycle. Models with an additional lateral wire survived significantly more cycles than those with a solitary 1.0-mm figure-of-eight wire, although caudal osteotomy displacements were not significantly different. Conversely, models with 1.25-mm wire allowed significantly smaller minimum and maximum displacements than those with 1.0-mm wire, but did not survive significantly more cycles. It therefore appears that clinical use of 1.25-mm wire may improve stability, while use of an additional lateral wire may improve durability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RESPONSE OF METACARPAL FRACTURE FIXATION CONSTRUCTS TO PHYSIOLOGICAL LOADINGS

This study compares the functional capabilities of different metacarpal fixation constructs under physiological loadings in an attempt to identify the optimal construct rather than the strongest one. One hundred and twenty-six preserved human metacarpals were mechanically tested after oblique osteotomies and internal fixation. Maximum load to failure, average structural rigidity, and energ...

متن کامل

Enhancing Performance of Infill Masonry With Skin reinforcement Subjected To Cyclic Load

Masonry infill has been widely used as building material due to its cost effectiveness and availability.  The failure of these masonry infill walls during the past earthquakes have underscored the importance of ensuring the safety of the infill walls when it is subjected to lateral loads. In-plane and out of plane failures have been observed in many reinforced concrete framed building with maso...

متن کامل

Comparison of clinical results of surgical treatment for unstable distal clavicle fractures by transacromial pins with and without tension band wire.

BACKGROUND An unstable distal clavicle fracture (Neer type II) is an indication that surgical intervention is required. Numerous treatment options have been introduced, but there is no gold standard. METHODS We report on our experience of 29 consecutive cases, between 2002 and 2008, of acute unstable distal clavicle fracture (Neer type II) and operative treatment using transacromial pins with...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Comparing hook plates and Kirschner tension band wiring for unstable lateral clavicle fractures.

The purpose of this study was to compare outcomes and complications of clavicular hook plate and Kirschner tension band wiring for fixation of unstable lateral clavicle fractures. The surgical outcomes of 92 consecutive patients (mean age, 49.30 ± 15.54 years) with unstable fractures of the lateral clavicle treated using AO clavicle hook plates were compared with those of 24 patients (mean age,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary and comparative orthopaedics and traumatology : V.C.O.T

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2006