Mechanical and Histopathological Comparison between Commercialized and Newly Designed Coronary Bare Metal Stents in a Porcine Coronary Restenosis Model

نویسندگان

  • Kyung Seob Lim
  • In Ho Bae
  • Jung Ha Kim
  • Dae Sung Park
  • Jong Min Kim
  • Jung Hyun Kim
  • Doo Sun Sim
  • Young Joon Hong
  • Myung Ho Jeong
چکیده

The aim of this study was to compare the stent designed by Chonnam National University Hospital (designated as CNUH) with commercial cobalt-chromium coronary stent in a porcine coronary overstretch restenosis model. CNUH stent was subjected to mechanical performance tests. Pigs were randomized into two groups in which the coronary arteries (10 pigs, 10 coronaries in each group) had either CNUH stent or control commercial bare metal stent. Histopathologic analysis was assessed at 28 days after stenting. In mechanical performance tests, CNUH stent showed 2.65N, 35.1N, 0.52N, 1.94%, 4.29% in the flat plate radial compression, radial force, 3 point bending, Foreshortening and recoil test, respectively. There was no significant difference in the injury score, internal elastic lamina (IEL), lumen area, neointima area, percent area stenosis, inflammation score and fibrin score between the two groups (1.2±0.35, 4.1±0.41 mm(2), 2.7±0.56 mm(2), 1.6±0.47 mm(2), 36.7±11.2%, 1.2±0.62, 0.2±0.34 in CNUH stent group vs. 1.2±0.38, 3.7±0.64 mm(2), 2.5±0.49 mm(2), 1.5±0.61 mm(2), 36.3±12.17%, 1.1±0.12, 0.4±0.46 in commercial stent group, respectively). In the mechanical performance test, CNUH stent showed the moderated performance under the guideline of FDA. CNUH stent demonstrated similar histological reactions compared with commercial cobalt-chromium stent in a porcine coronary overstretch restenosis model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of an Alpha-4 Integrin Inhibitor on Restenosis in a New Porcine Model Combining Endothelial Denudation and Stent Placement

Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where restenosis is assessed after endothelial abrasion of the arterial wall or stent implantation. We combined endothelial cell denudation and implantation of stents to develop a new clinically relevant ...

متن کامل

Primary Stenting of Totally Occluded Native Coronary Arteries II (PRISON II): a randomized comparison of bare metal stent implantation with sirolimus-eluting stent implantation for the treatment of total coronary occlusions.

BACKGROUND Sirolimus-eluting stents markedly reduce the risk of restenosis compared with bare metal stents. However, it is not known whether there are differences in effectiveness between bare metal and sirolimus-eluting stents in patients with total coronary occlusions. METHODS AND RESULTS In a prospective, randomized, single-blind, 2-center trial, we enrolled 200 patients with total coronar...

متن کامل

Choice of Drug Eluting Stent: A Review

The development of stent has been a major achievement in treating obstructive coronary artery disease (OCAD). The main obstacle in the long term success of percutaneous coronary intervention (PCI) was the neo-intimal hyperplasia developed within the stent, which may leads to instent restenosis. The introduction of Drug-eluting stents (DES) shows steep decrease in angiographic restenosis when co...

متن کامل

Comparison of the Efficacy of Paclitaxel-Eluting Balloon Catheters and Everolimus-Eluting Stents in the Treatment of Coronary In-Stent Restenosis

Coronary stent implantation has significantly improved percutaneous coronary intervention and enabled the management of early complications of plain balloon angioplasty (POBA). By preventing elastic recoil and constrictive remodeling, coronary stent implantation decreases the frequency of restenosis after percutaneous coronary intervention. However, a new complication has accompanied these impr...

متن کامل

Comparison of stent graft, sirolimus stent, and bare metal stent implanted in patients with acute coronary syndrome: clinical and angiographic follow-up.

AIM To compare polytetrafluoroethylene stent graft (PTFE) with sirolimus and bare metal stents in reducing in-stent restenosis in native coronary vessels in patients with acute coronary syndrome. METHODS The study included patients who underwent stent implantation in acute coronary syndrome from January 2003 to May 2004. The patients (n=119) were randomized either to stent graft group (n=40),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2013