Large amounts of mineral oil are used in electrical equipments as insulation and cooling medium. To avoid damages and cut-off of power electricity supply it is necessary to evaluate the mineral oil condition. Lifetime estimation of mineral oil which is based on accelerated thermal ageing at three temperatures (according to IEC 60216-1/2001) requires a long experimental time. This standardized method permits the lifetime calculation using a model based on the equation lnDðTÞ 1⁄4 aþ b T, where a is the intercept and the slope of the plot lnsx versus 1/T, b is a material constant, T is the accelerated ageing temperature and sx is the time to reach the acceptable limit value of a chosen degradation parameter. In the present paper, mineral oil lifetime at 80 C (D1 = 1.53 10 h) has been obtained on the basis of accelerated ageing tests at three different temperatures (115 C, 135 C and 155 C) and choosing the oil electrical resistivity (q) as degradation parameter. The activation energy of the ageing process determined in these conditions was 101.8 kJ/mol. To reduce the test duration, this paper proposes a simpler method based on a single ageing test at a higher temperature and the activation energy of the oxidation reaction being determined from non-isothermal Differential Scanning Calorimetry (DSC) measurements. According to the proposed method, the plot q versus s (ageing time) was drawn only for the accelerated ageing temperature T = 155 C and the lifetime value (sx) for this temperature was experimentally obtained. In this case, the activation energy value Ea corresponding to oxidation reaction was determined (Ea = 102.4 kJ/mol). Based on both Ea and the sx at 155 C, the lifetime at 80 C (D2 = 1.86 10 h) was determined and compared with D1. The differences between D1 and D2 values are acceptable and the proposed method is effective in terms of costs and experimental time (the experimental time is reduced by a factor of 12–14) as compared to the present standardized method. 2013 Elsevier Ltd. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

Application of Physical-Chemical Data in Estimation of Dissolved Gases in Insulating Mineral Oil for Power Transformer Incipient Fault Diagnosis with ANN

In this paper, Artificial Neural Networks are used to solve a complex problem concerning to power transformers and characterized by non-linearity and hard dynamic modeling. The operation conditions and integrity of a power transformer can be detected by analysis of physical-chemical and chromatographic isolating oil, allowing establish procedures for operating and maintaining the equipment. How...

متن کامل

Characteristics of Mineral Oil-based Nanofluids for Power Transformer Application

Received Feb 7, 2017 Revised Apr 5, 2017 Accepted Apr 29, 2017 Trends in the field of nanomaterial-based transformer oil show most of the conducted works have focused only on the transformer oil-based nanofluids but limited studies on the stability of transformer oil-based nanofluids. Since mineral oil-based nanofluids still can produce the sedimentation, thus the cold-atmospheric pressure plas...

متن کامل

Different Electric Vehicle Charging Strategies to avoid Reducing the Insulation Oil Lifetime of Distribution Transformers

Abstract: The widespread presence of uncontrolled electric vehicles causes overloading of distribution network equipment. One of these equipments is distribution transformer, which should pay attention to overloading and reducing lifetime of this equipment due to charging of electric vehicles. First, strategies have been proposed to investigate the effect of electric vehicle penetration level a...

متن کامل

A Novel Approach of Transformer Oil Quality Analysis Using Image Processing

Electrical energy is the paramount need in a nation’s development. To cater for large demand for electricity there is a need for reliable and proficient power system. For a power system to work reliably, the role of Transformers is critical. Health of the transformer mainly depends on its insulation. Among the different insulating material used in transformers, mineral oil is the most widely us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016