Cardiac Output by the Dilution Method without Arterial Sampling
نویسنده
چکیده
The selection of an external site for a radioisotope determination of cardiac output is discussed with respect to satisfying the analytical conditions of the Stewart-Hamilton dilution equation. Examples of both single-chamber and multichamber recording are illustrated, along with a discussion of the difficulties of curve calibration and extrapola. tion from multiple sites. The development of a method independent of critical placement or patient variability is described.
منابع مشابه
The determination of cardiac output by the dilution method without arterial sampling. II. Validation of precordial recording.
The selection of an external site for a radioisotope determination of cardiac output is discussed with respect to satisfying the analytical conditions of the Stewart-Hamilton dilution equation. Examples of both single-chamber and multichamber recording are illustrated, along with a discussion of the difficulties of curve calibration and extrapola. tion from multiple sites. The development of a ...
متن کاملThe Determination of Cardiac Output by the Dilution Method without Arterial Sampling
The selection of an external site for a radioisotope determination of cardiac output is discussed with respect to satisfying the analytical conditions of the Stewart-Hamilton dilution equation. Examples of both single-chamber and multichamber recording are illustrated, along with a discussion of the difficulties of curve calibration and extrapola. tion from multiple sites. The development of a ...
متن کاملPulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery.
BACKGROUND Cardiac output is often monitored after cardiac operations with a pulmonary artery catheter. A new method has been introduced that measures cardiac output by lithium dilution (LiDCO) and uses these data to calibrate a system (PulseCO) that calculates cardiac output continuously from the energy of the arterial pressure waveform. It is unknown whether PulseCO measurements are valid ear...
متن کاملValidity of indicator-dilution determinations of cardiac output in patients with mitral regurgitation.
mHE indicator-dilution method has been widely employed for determination of cardiac output since its introduction by Stewart' and Hamilton and associates.2 The effect of unrecognized recirculation of indicator particles upon the primary indicator time-concentration curve has caused concern as to whether this method may be employed in such conditions as mitral regurgitation3' 4and as to whether ...
متن کاملRadioactive Isotope Determination of Myocardial Blood
ESTIMATION of cardiac output by the indicator-dilution method has been described by Kinsman, Moore, and Hamilton1 utilizing dye; however, radioactive methods for determination of cardiac output owe their inception to Prinzmetal and co-workers,2 who recorded radioactivity as a function of time by means of a counter over the heart after an intravenous injection of radioactive Na24. Nylin and Cela...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -