Development of An Impedimetric Aptasensor for the Detection of Staphylococcus aureus
نویسندگان
چکیده
In combination with electrochemical impedance spectroscopy, aptamer-based biosensors are a powerful tool for fast analytical devices. Herein, we present an impedimetric aptasensor for the detection of the human pathogen Staphylococcus aureus. The used aptamer targets protein A, a surface bound virulence factor of S. aureus. The thiol-modified protein A-binding aptamer was co-immobilized with 6-mercapto-1-hexanol onto gold electrodes by self-assembly. Optimization of the ratio of aptamer to 6-mercapto-1-hexanol resulted in an average density of 1.01 ± 0.44 × 1013 aptamer molecules per cm². As shown with quartz crystal microbalance experiments, the immobilized aptamer retained its functionality to bind recombinant protein A. Our impedimetric biosensor is based on the principle that binding of target molecules to the immobilized aptamer decreases the electron transfer between electrode and ferri-/ferrocyanide in solution, which is measured as an increase of impedance. Microscale thermophoresis measurements showed that addition of the redox probe ferri-/ferrocyanide has no influence on the binding of aptamer and its target. We demonstrated that upon incubation with various concentrations of S. aureus, the charge-transfer resistance increased proportionally. The developed biosensor showed a limit of detection of 10 CFU·mL-1 and results were available within 10 minutes. The biosensor is highly selective, distinguishing non-target bacteria such as Escherichia coli and Staphylococcus epidermidis. This work highlights the immense potential of impedimetric aptasensors for future biosensing applications.
منابع مشابه
Development of electrochemical aptasensor based on gold nanorod and its application for detection of aflatoxin B1 in rice and blood serum sample
Aflatoxins are a group of fungal mycotoxins produced mainly by molds, e.g. Aspergillus flavus and Aspergillus parasiticus. Among Aflatoxins, Aflatoxin B1 (AFB1) is the most toxic. Therefore, there is a prompt need for determination of AFB1 in food products. This paper reports an electrochemical aptasensor for accurate determination of AFB1, which was constructed by the using gold nanorod sensin...
متن کاملDetection of Methicillin Resistant Staphylococcus aureus (MRSA) by CHROMagar Versus Cefoxitin Disk Diffusion Method
Methicillin resistant Staphylococcus aureus (MRSA) has been emerged as a nosocomial and community acquired pathogen worldwide. There are many challenges for laboratory detection of MRSA. The aim of this study was to compare different phenotypic methods with PCR based method as a gold standard for detection of mecA gene to detection of MRSA. A total of 220 clinical isolates of S. aureus which w...
متن کاملImpedimetric Aptasensor for Ochratoxin A Determination Based on Au Nanoparticles Stabilized with Hyper-Branched Polymer
An impedimetric aptasensor for ochratoxin A (OTA) detection has been developed on the base of a gold electrode covered with a new modifier consisting of electropolymerized Neutral Red and a mixture of Au nanoparticles suspended in the dendrimeric polymer Botlorn H30®. Thiolated aptamer specific to OTA was covalently attached to Au nanoparticles via Au-S bonding. The interaction of the aptamer w...
متن کاملDetection of lead ions using an electrochemical aptasensor
The aim of this research was to develop a simple, selective and sensitive aptasensor for detection of Pb2+ based on hairpin structure of complementary strand (CS) of aptamer (Apt). Screen printed carbon electrode (SPCE) was electrodeposited by gold nanoparticles to be used as the substrate for the immobilization of Apt-CS. Moreover, gold nanoparticles (AuNPs) and thionine were added to increase...
متن کاملDetection Of Methicillin Resistance In Staphylococcus Aureus By Disk Diffusion And PCR Methods
Background and Objective: Methicillin resistance in Staphylococcus aureus is an increasingly important clinical problem. A chromosomal gene, mecA, mediates resistance to penicillinase-resistant penicillins such as methicillin and oxacillin in Staphylococcus aureus. We evaluated the validity of disk diffusion test by using oxacillin, methicillin an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -