Noninvasive optical cytochrome c oxidase redox state measurements using diffuse optical spectroscopy.

نویسندگان

  • Jangwoen Lee
  • Jae G Kim
  • Sari B Mahon
  • David Mukai
  • David Yoon
  • Gerry R Boss
  • Steven E Patterson
  • Gary Rockwood
  • Gary Isom
  • Matthew Brenner
چکیده

A major need exists for methods to assess organ oxidative metabolic states in vivo. By contrasting the responses to cyanide (CN) poisoning versus hemorrhage in animal models, we demonstrate that diffuse optical spectroscopy (DOS) can detect cytochrome c oxidase (CcO) redox states. Intermittent decreases in inspired O2 from 100% to 21% were applied before, during, and after CN poisoning, hemorrhage, and resuscitation in rabbits. Continuous DOS measurements of total hemoglobin, oxyhemoglobin, deoxyhemoglobin, and oxidized and reduced CcO from muscle were obtained. Rabbit hemorrhage was accomplished with stepwise removal of blood, followed by blood resuscitation. CN treated rabbits received 0.166  mg/min NaCN infusion. During hemorrhage, CcO redox state became reduced concurrently with decreases in oxyhemoglobin, resulting from reduced tissue oxygen delivery and hypoxia. In contrast, during CN infusion, CcO redox state decreased while oxyhemoglobin concentration increased due to CN binding and reduction of CcO with resultant inhibition of the electron transport chain. Spectral absorption similarities between hemoglobin and CcO make noninvasive spectroscopic distinction of CcO redox states difficult. By contrasting physiological perturbations of CN poisoning versus hemorrhage, we demonstrate that DOS measured CcO redox state changes are decoupled from hemoglobin concentration measurement changes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive in vivo monitoring of cyanide toxicity and treatment using diffuse optical spectroscopy in a rabbit model.

Currently, no reliable noninvasive methods exist for monitoring the severity of in vivo cyanide (CN) toxicity, treatment, and resulting physiological changes. We developed a broadband diffuse optical spectroscopy (DOS) system to measure bulk tissue absorption and scattering. DOS was used to optically monitor CN toxicity and treatment with sodium nitrite (NaNO2). To perform experiments, the DOS ...

متن کامل

Use of mitochondrial inhibitors to demonstrate that cytochrome oxidase near-infrared spectroscopy can measure mitochondrial dysfunction noninvasively in the brain.

The use of near-infrared spectroscopy to measure noninvasively changes in the redox state of cerebral cytochrome oxidase in vivo is controversial. We therefore tested these measurements using a multiwavelength detector in the neonatal pig brain. Exchange transfusion with perfluorocarbons revealed that the spectrum of cytochrome oxidase in the near-infrared was identical in the neonatal pig, the...

متن کامل

Image reconstruction of oxidized cerebral cytochrome C oxidase changes from broadband near-infrared spectroscopy data.

In diffuse optical tomography (DOT), overlapping and multidistance measurements are required to reconstruct depth-resolved images of oxy- ([Formula: see text]) and deoxy- (HHb) hemoglobin concentration changes occurring in the brain. These can be considered an indirect measure of brain activity, under the assumption of intact neurovascular coupling. Broadband systems also allow changes in the r...

متن کامل

Non-invasive optical spectroscopy and imaging of human brain function.

Brain activity is associated with changes in optical properties of brain tissue. Optical measurements during brain activation can assess haemoglobin oxygenation, cytochrome-c-oxidase redox state, and two types of changes in light scattering reflecting either membrane potential (fast signal) or cell swelling (slow signal), respectively. In previous studies of exposed brain tissue, optical imagin...

متن کامل

Principles, techniques, and limitations of near infrared spectroscopy.

In the last decade the study of the human brain and muscle energetics underwent a radical change, thanks to the progressive introduction of noninvasive techniques, including near-infrared (NIR) spectroscopy (NIRS). This review summarizes the most recent literature about the principles, techniques, advantages, limitations, and applications of NIRS in exercise physiology and neuroscience. The mai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2014