Determining the rotational alignment of the tibial component at total knee replacement: a comparison of two techniques.
نویسندگان
چکیده
We prospectively assessed the benefits of using either a range-of-movement technique or an anatomical landmark method to determine the rotational alignment of the tibial component during total knee replacement. We analysed the cut proximal tibia intraoperatively, determining anteroposterior axes by the range-of-movement technique and comparing them with the anatomical anteroposterior axis. We found that the range-of-movement technique tended to leave the tibial component more internally rotated than when anatomical landmarks were used. In addition, it gave widely variable results (mean 7.5 degrees ; 2 degrees to 17 degrees ), determined to some extent by which posterior reference point was used. Because of the wide variability and the possibilities for error, we consider that it is inappropriate to use the range-of-movement technique as the sole method of determining alignment of the tibial component during total knee replacement.
منابع مشابه
Combined Rotational Alignment Change after Total Knee Arthroplasty in Different Tibial Component Designs: Implications for Optimal Tibial Component Rotational Alignment
Purpose The rotational alignment of the femoral and tibial components is closely related to the results after total knee arthroplasty (TKA). In this study, we measured the combined rotational alignment change (ΔCR) after TKA and compared the different influence of symmetric and asymmetric tibial component designs on the combined rotational alignment. Materials and Methods Eighty-four patients...
متن کاملEarly Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience
Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...
متن کاملProsthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations
BACKGROUND Clinical consequences of alignment errors in total knee replacement (TKR) have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components' relative positi...
متن کاملRotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border
This study compares two different methods of aligning the tibial component in a total knee arthroplasty, one by aligning the component with the border between the medial one third and lateral two thirds of the tibial tubercle and the other by allowing the component to seek its own position as the knee is taken through a range of motion. The first technique emphasizes the need to maintain an app...
متن کاملRelationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty
This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-stabilized (PS) symmetric tibial baseplate while Group 2 included 24 females and 16 males receivin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 1 شماره
صفحات -
تاریخ انتشار 2007