WFC 3 TV 2 Testing : UVIS - 2 Read Noise
نویسنده
چکیده
We examine the read noise of the spare UVIS-2 detector of the Wide Field Camera 3 during its second thermal vacuum campaign at the Goddard Space Flight Center. Only the frames acquired in the default readout mode are considered : a gain = 1.5 e/DN, a four amplifier readout (ABCD), and no on-chip binning. The read noise is calculated from the serial virtual overscan region of each quadrant. From a sample of ~600 frames at an operating temperature of -78 C, the read noise is 3.17± 0.02, 3.15± 0.08, 3.20 ± 0.03, and 3.27 ± 0.02 e for amplifiers A, B, C, and D, respectively. At a temperature of 81 C (and from a smaller sample), the read noise is lower by ~0.6% for amps A and B and by ~1.4% for amps C and D. A weak positive correlation is found between the read noise and the median level of the imaging areas for amps C and D, possibly from a nonperfect serial transfer of the charge. The variation is very small, roughly 0.05 e (1.5%) or less over a range of imaging levels of 10000 e to 60000 e. Similarly, a weak negative correlation is found for amplifiers A and B. The CEI specification of a read noise of < 4 e is easily met for an operating detector temperature of < -20 C. There is no difference in the read noise between instrument sides 1 and 2. In an appendix, we present and analyze the superbias frame. A weak residual odd/even effect is observed in each quadrant and the ovsercan regions. The peak-to-peak amplitude of the effect is 0.01-0.03 e for amps A,C,D and ~0.4 e for amp B. The presence of this pattern will be checked for the flight detector and if necessary, proper modifications to calwf3 will be explored to minimize its impact. Operated by the Association of Universities for Research in Astronomy, Inc., for the National Aeronautics and Space Administration
منابع مشابه
WFC3 TV3 Testing: UVIS-1′ and IR-4 Noise Trends
We examine the read noise of the flight UVIS-1′ detector of the Wide Field Camera 3 during its third thermal vacuum campaign at the Goddard Space Flight Center. Only the frames acquired at the default gain of 1.5 e/DN and four amplifier readout (ABCD) are considered. The read noise at a temperature of -82 C and for no on-chip binning, calculated from the pairwise subtraction of bias frames, is ...
متن کاملWFC 3 2008 - 32 WFC 3 Optical Alignment Characterization in Thermal - Vacuum Test # 3
We have performed an assessment of the optical alignment of the WFC3 instrument in its final flight configuration, including the UVIS-1’ and IR-4 detectors, during the 3 thermal-vac test in March 2008. Both detectors are found to be aligned to well within tolerance in all degrees of freedom. The corrector settings, after adjustment to optimize image quality, are within the budgeted range for gr...
متن کاملWFC 3 SMOV Program 11427 : UVIS Channel Shutter Shading
A series of internal flat field images and standard star observations were used to quantify the behavior of the UVIS channel shutter mechanism. Photometry of the stars and flat field analysis show that the UVIS shutter functionality in SMOV is comparable to that in ground testing. Shutter shading causes a variation in exposure time across the detector of no more than 0.0009 seconds. On-orbit ra...
متن کاملWFC3 Thermal Vacuum Testing: UVIS Crosstalk
The integrated WFC3 instrument recently underwent testing under thermal vacuum (TV) conditions in the GSFC SES (Goddard Space Flight Center Space Environment Simulator). This report summarizes the behavior of the UVIS channel crosstalk features seen in the TV data as compared to the behavior seen in previous data taken under ambient conditions in early 2004 and provides an update on the hardwar...
متن کاملUsing global PSF properties to probe the WFC 3 UVIS
This ISR briefly reviews how the WFC3 UVIS channel focus and alignment impact the PSF. The aim is to verify whether we can identify any simple PSF measurement that would allows to monitor these quantities. We find that the centering of the PSF within a pixel is a crucial parameter that needs to be calibrated or corrected for and that PSF sharpness is the most promising parameter.