Coronary stent symmetry and vascular injury determine experimental restenosis.

نویسندگان

  • C Schulz
  • R A Herrmann
  • C Beilharz
  • J Pasquantonio
  • E Alt
چکیده

OBJECTIVE To assess the impact of stent symmetry on restenosis using the coronary overstretch sheep model. METHODS Neointimal thickness, injury index, and percentage diameter and area stenosis were calculated by digital morphometry. The standard deviation of the angular burden was used to assess stent symmetry for each section. MATERIALS 15 healthy Merino sheep (63-75 kg) underwent implantation of 30 slotted tube stents (7 mm). Restenosis was induced by calculated overstretch of the coronary artery. Twenty eight days after implantation, stents were excised and underwent histological examination using quantitative digital morphometry. RESULTS The severity of vessel injury was positively correlated with neointimal thickness and with percentage diameter and area stenosis (p < 0.001). Mean neointimal thickness and mean vascular injury per cross section were strongly related to the standard deviation of angular burden, with correlation coefficients of 0.6 and 0.8, respectively (p < 0.001). CONCLUSIONS The well known relation between vascular injury and restenosis was confirmed, and a new relation was discovered between stent asymmetry and restenosis. If these results apply to human coronary arteries, restenosis may also be dependent on the degree of asymmetric stent expansion. These results should influence the development of new stent designs to reduce asymmetric stent expansion, leading to a more homogeneous strain distribution in stented coronary segments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MicroRNAs for Restenosis and Thrombosis After Vascular Injury.

Percutaneous revascularization revolutionized the therapy of patients with coronary artery disease. Despite continuous technical advances that substantially improved patients' outcome after percutaneous revascularization, some issues are still open. In particular, restenosis still represents a challenge, even though it was dramatically reduced with the advent of drug-eluting stents. At the same...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Morphological predictors of restenosis after coronary stenting in humans.

BACKGROUND Experimental studies suggest that arterial injury and inflammation lead to increased neointimal growth after stenting. Despite the increased use of coronary stents in humans, there are only limited pathological data on the morphological features of in-stent restenosis. METHODS AND RESULTS Detailed histology was performed on 116 stents, implanted > or =90 days in 87 coronary arterie...

متن کامل

Association of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent

In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...

متن کامل

Finite Element Analysis of a Stent Implantation in a Stenosed Artery

Instent restenosis (ISR) has been a key factor that restricts the further use of intraoronary stents. And the mechanical interaction between the stent and the artery has been indicated as one of the significant causes for the activation of stent-related restenosis. However, there is very little quantitative information about the interaction of stent with artery. In order to improve the general ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 2000