Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice
نویسندگان
چکیده
Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one-dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high-temporal-resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user-independent technique. Here, we investigated the performance of high-temporal-resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in-house, high-temporal-resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom-made, open-source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high-frequency, pulsed-wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high-temporal-resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high-temporal-resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high-temporal-resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression.
منابع مشابه
Mitral valve annular velocity measurements derived from cine MRI: validation against Doppler echocardiography
Assessment of mitral annular tissue velocity plays an essential role in the evaluation of diastolic dysfunction. We have previously shown that mitral annular velocities can be derived from standard four-chamber cine SSFP images by automatically detecting and tracking the mitral valve insertion points [1]. However, this method has not been validated against tissue Doppler echocardiography, the s...
متن کاملUltrafast Cine cardiac MRI in the assessment of left ventricular diastology
Methods 18 self-reported healthy volunteers (12 men, average age 35 years) and 6 patients with diastolic dysfunction (4 men, average age 52 years) underwent cardiac MRI on an investigational 1.5T cardiovascular magnet (Aera, Siemens Medical Solutions, Erlangen Germany). All subjects underwent ultrafast cine MR imaging in four and two chamber orientations (nominal TR 5.5 15.3 msec, heart rate de...
متن کاملLeft ventricular inflow propagation velocity for diastolic function testing: head-to-head comparison between velocity-encoded MRI and color M-mode Doppler echocardiography
Background The inflow propagation velocity (Vprop) of the early filling wave has been proposed as an accurate marker of left ventricular (LV) diastolic function [1]. Traditionally, Color M-mode echo Doppler is used for Vprop-assessment. However, this method has not been validated against an alternative modality such as velocity-encoded (VE) MRI for assessing Vprop. The purpose of this study was...
متن کاملDetecting left ventricular impaired relaxation in cardiac MRI using moving mesh correspondences
UNLABELLED Anatomical cine cardiovascular magnetic resonance (CMR) imaging is widely used to assess the systolic cardiac function because of its high soft tissue contrast. Assessment of diastolic LV function has not regularly been performed due the complex and time consuming procedures. This study presents a semi-automated assessment of the left ventricular (LV) diastolic function using anatomi...
متن کاملDevelopmental changes of cardiac function and mass assessed with MRI in neonatal, juvenile, and adult mice.
Cardiovascular transgenic mouse models with an early phenotype or even premature death require noninvasive imaging methods that allow for accurate visualization of cardiac morphology and function. Thus the purpose of our study was to assess the feasibility of magnetic resonance imaging (MRI) to characterize cardiac function and mass in newborn, juvenile, and adult mice. Forty-five C57bl/6 mice ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 30 شماره
صفحات -
تاریخ انتشار 2017