Design of iterative ROI transmission tomography reconstruction procedures and image quality analysis.
نویسندگان
چکیده
PURPOSE An iterative edge-preserving CT reconstruction algorithm for high-resolution imaging of small regions of the field of view is investigated. It belongs to a family of region-of-interest reconstruction techniques in which a low-cost pilot reconstruction of the whole field of view is first performed and then used to deduce the contribution of the region of interest to the projection data. These projections are used for a high-resolution reconstruction of the region of interest (ROI) using a regularized iterative algorithm, resulting in significant computational savings. This paper examines how the technique by which the pilot reconstruction of the full field of view is obtained affects the total runtime and the image quality in the region of interest. METHODS Previous contributions to the literature have each focused on a single approach for the pilot reconstruction. In this paper, two such approaches are compared: the filtered backprojection and a low-resolution regularized iterative reconstruction method. ROI reconstructions are compared in terms of image quality and computational cost over simulated and physical phantom (Catphan600) studies, in order to assess the compromises that most impact the quality of the ROI reconstruction. RESULTS With the simulated phantom, new artifacts that appear in the ROI images are caused by significant errors in the pilot reconstruction. These errors include excessive coarseness of the pilot image grid and beam-hardening artifacts. With the Catphan600 phantom, differences in the imaging model of the scanner and that of the iterative reconstruction algorithm cause dark border artifacts in the ROI images. CONCLUSIONS Inexpensive pilot reconstruction techniques (analytical algorithms, very-coarse-grid penalized likelihood) are practical choices in many common cases. However, they may yield background images altered by edge degradation or beam hardening, inducing projection inconsistency in the data used for ROI reconstruction. The ROI images thus have significant streak and speckle artifacts, which adversely affect the resolution-to-noise compromise. In these cases, edge-preserving penalized-likelihood methods on not-too-coarse image grids prove to be more robust and provide the best ROI image quality.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملPhysical-Space Refraction-Corrected Transmission Ultrasound Computed Tomography Made Computationally Practical
Transmission Ultrasound Computed Tomography (CT) is strongly affected by the acoustic refraction properties of the imaged tissue, and proper modeling and correction of these effects is crucial to achieving high-quality image reconstructions. A method that can account for these refractive effects solves the governing Eikonal equation within an iterative reconstruction framework, using a wave-fro...
متن کامل3D ROI Image Reconstruction from Truncated Computed Tomography
This paper introduces a novel method for accurate region-of-interest (ROI) reconstruction from 3D computed tomography (CT), consisting of a wavelet-based regularized iterative reconstruction procedure which is guaranteed to converge to an exact or highly accurate solution within the ROI. ROI tomography is motivated by the goal to reduce the overall radiation exposure when primarily the reconstr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 37 9 شماره
صفحات -
تاریخ انتشار 2010