Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results.

نویسندگان

  • Mark S Wathen
  • Paul J DeGroot
  • Michael O Sweeney
  • Alice J Stark
  • Mary F Otterness
  • Wayne O Adkisson
  • Robert C Canby
  • Koroush Khalighi
  • Christian Machado
  • Donald S Rubenstein
  • Kent J Volosin
چکیده

BACKGROUND Successful antitachycardia pacing (ATP) terminates ventricular tachycardia (VT) up to 250 bpm without the need for painful shocks in implantable cardioverter-defibrillator (ICD) patients. Fast VT (FVT) >200 bpm is often treated by shock because of safety concerns, however. This prospective, randomized, multicenter trial compares the safety and utility of empirical ATP with shocks for FVT in a broad ICD population. METHODS AND RESULTS We randomized 634 ICD patients to 2 arms-standardized empirical ATP (n=313) or shock (n=321)-for initial therapy of spontaneous FVT. ICDs were programmed to detect FVT when 18 of 24 intervals were 188 to 250 bpm and 0 of the last 8 intervals were >250 bpm. Initial FVT therapy was ATP (8 pulses, 88% of FVT cycle length) or shock at 10 J above the defibrillation threshold. Syncope and arrhythmic symptoms were collected through patient diaries and interviews. In 11+/-3 months of follow-up, 431 episodes of FVT occurred in 98 patients, representing 32% of ventricular tachyarrhythmias and 76% of those that would be detected as ventricular fibrillation and shocked with traditional ICD programming. ATP was effective in 229 of 284 episodes in the ATP arm (81%, 72% adjusted). Acceleration, episode duration, syncope, and sudden death were similar between arms. Quality of life, measured with the SF-36, improved in patients with FVT in both arms but more so in the ATP arm. CONCLUSIONS Compared with shocks, empirical ATP for FVT is highly effective, is equally safe, and improves quality of life. ATP may be the preferred FVT therapy in most ICD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial.

BACKGROUND Implantable cardioverter defibrillators (ICDs) reduce mortality in primary and secondary prevention. Quality of life, mortality, appropriate therapies for specific ventricular rhythms, and inappropriate therapies for supraventricular tachycardia (SVT) were compared among 582 patients (primary prevention=248; secondary prevention=334) in PainFREE Rx II, a 634-patient prospective, rand...

متن کامل

Appropriate and Inappropriate Ventricular Therapies, Quality of Life, and Mortality Among Primary and Secondary Prevention Implantable Cardioverter Defibrillator Patients

Background—Implantable cardioverter defibrillators (ICDs) reduce mortality in primary and secondary prevention. Quality of life, mortality, appropriate therapies for specific ventricular rhythms, and inappropriate therapies for supraventricular tachycardia (SVT) were compared among 582 patients (primary prevention 248; secondary prevention 334) in PainFREE Rx II, a 634-patient prospective, rand...

متن کامل

Optimizing Antitachycardia Pacing

Implantable cardioverter-defibrillators (ICDs) substantially reduce sudden cardiac death. Paradoxically, even though ICDs are implanted to prevent sudden cardiac death by delivering therapies, appropriate and inappropriate ICD shocks have been associated with an increased risk of mortality.1 However, patients treated with ICD shocks show even poorer survival than patients treated with antitachy...

متن کامل

Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease.

BACKGROUND Implantable cardioverter-defibrillators (ICDs) can terminate some ventricular tachycardias (VTs) painlessly with antitachycardia pacing (ATP). ATP has not routinely been applied for VT >188 bpm because of concerns about efficacy, risk of acceleration, and delay of definitive shock therapy. This prospective, multicenter study evaluated the efficacy of empirical ATP to terminate fast V...

متن کامل

Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review

Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 110 17  شماره 

صفحات  -

تاریخ انتشار 2004