Comparison of calcification specificity in digital mammography using soft-copy display versus screen-film mammography.

نویسندگان

  • Hak Hee Kim
  • Etta D Pisano
  • Elodia B Cole
  • Michael R Jiroutek
  • Keith E Muller
  • Yuanshui Zheng
  • Cherie M Kuzmiak
  • Marcia A Koomen
چکیده

OBJECTIVE The purpose of this study was to compare specificity in the interpretation of calcifications in soft-copy reviewing of digital mammograms versus hard-copy reviewing of screen-film mammograms. MATERIALS AND METHODS A total of 130 consecutive cases with calcifications (44 malignant and 86 benign) that had been evaluated with needle or surgical biopsy were collected. Both screen-film mammography and soft-copy digital mammography were obtained in the same patients under existing research protocols using Fischer Imaging's SenoScan (n = 71), Lorad's digital mammography system (n = 35), and GE Healthcare's Senographe 2000D (n = 24). Eight trained radiologists scored all lesions--cropped or masked to display just the region of interest--both on screen-film and soft-copy digital mammography with a month between reviews to reduce the effects of learning and memory. A 5-point malignancy scale was used, with 1 as definitely not, 2 as probably not, 3 as possibly, 4 as probably, and 5 as definitely. Reviewers were randomly assigned condition order, and images within each condition were randomly ordered. Repeated measures analysis of variance was used to test for differences between conditions in specificity computed via nonparametric receiver operating characteristic (ROC) study separately for each reviewer and condition. RESULTS Across all reviewers, the mean specificity for 1 or 2 versus 3, 4, or 5 was 0.803 for screen-film mammography (range, 0.413-0.938; SD +/- 0.166) and 0.833 for soft-copy image (range, 0.375-0.951; SD +/- 0.187). Although not statistically significant (Student's t test p values from 0.19 to 0.99 across all cut points), numeric values of specificity were consistently higher for soft-copy versus screen-film mammography. No statistical significance in specificity was seen using all possible cut points in the 5-point scale, although the primary analysis used the cutpoint for differentiation between benign and malignant cases as 1 or 2 versus 3, 4, or 5. CONCLUSION No statistically significant difference was shown in specificity achievable using soft-copy digital versus screen-film mammography in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display.

PURPOSE To compare the speed and accuracy of the interpretations of digital mammograms by radiologists by using printed-film versus soft-copy display. MATERIALS AND METHODS After being trained in interpretation of digital mammograms, eight radiologists interpreted 63 digital mammograms, all with old studies for comparison. All studies were interpreted by all readers in soft-copy and printed-f...

متن کامل

The effects of gray scale image processing on digital mammography interpretation performance.

RATIONALE AND OBJECTIVES To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. MATERIALS AND METHODS A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and convention...

متن کامل

A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...

متن کامل

Epidemiology, Prevention, Screening

Background: Over 90% of mammography machines in Japan have already become digital, however, almost three-fourths of them utilize computed radiography (CR). The majority of them necessitate hard copy diagnosis. Therefore, reliability of soft-copy interpretation of CR mammography is still controversial. The purpose of this study is to assess the usefulness and problems of soft-copy interpretation...

متن کامل

Digital mammography.

IN 1992, A NATIONAL Cancer Institute expert panel determined that, of all emergent technologies, full-field digital mammography (FFDM) held the greatest potential for improving breast cancer detection.1,2 The transition to digital mammography is a necessary step in the ongoing process of improving mammographic image quality and advancing toward the goal of earlier breast cancer detection. Digit...