Complications resulting from tracker pin-sites in computer navigated knee replacement surgery.
نویسندگان
چکیده
Intra-osseous pin sites used in Computer Navigated knee Arthroplasty are known to cause complications including infection, neurovascular injury, thermal necrosis and peri-prosthetic fracture. Many studies have looked at ways of reducing these risks to improve results in computer-navigated surgery. We present our complication rates and techniques used to reduce complications in a retrospective study of 321 patients performed by a single surgeon in between 2009 and 2013. One patient was identified with a superficial pin site infection. No major complications were recorded during a mean follow up period of 31 months. Attention to detail in every aspect of pin insertion reduces the rates of both minor and major complications. In particular rates of peri-prosthetic fracture were shown to be lower when using a uni-cortical drilling technique compared with the use of bicortical drilling in other studies.
منابع مشابه
Complications of fixed infrared emitters in computer-assisted total knee arthroplasties
BACKGROUND The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of these tracker-pins, the necessary time to fix them to the bone and the possible advantages of a new femora...
متن کاملAging Effect on Femoral Stress Fracture Risk after Computer-navigated Total Knee Arthroplasty
INTRODUCTION Recent clinical studies have shown that computer navigation for total knee arthroplasty (TKA) provides improved component alignment accuracy, and can help to avoid femoral malrotation and errors in axial alignment [1]. However, femoral stress fracture after computernavigated TKA has been reported due to the pin hole [2] and we hypothesized that osteoporosis would be one of the key ...
متن کاملImageless computer navigation in total knee arthroplasty.
OBJECTIVES To study the difference in clinical and radiological outcomes between imageless computer-navigated and the conventional technique for performing total knee arthroplasty. DESIGN Prospective case-control study. SETTING University teaching hospital, Hong Kong. PATIENTS Forty-seven patients with imageless computer-navigated total knee arthroplasty were matched with 47 patients with...
متن کاملFatigue fracture of the femur after navigated total knee replacement.
We present a case of fatigue fracture of the femur after navigated total knee arthroplasty with the Orthopilot system. A 60-year-old woman with rheumatoid arthritis and osteoporosis (T-score = -3.1) reported increasing pain of the thigh 8 weeks after the surgery. A fatigue fracture of the right femur through the pinholes was diagnosed and stabilized with an intramedullary nail, achieving union ...
متن کاملShort-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008
BACKGROUND and purpose Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. PATIENTS AND METHODS Primary total knee rep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 81 4 شماره
صفحات -
تاریخ انتشار 2015