Seasonal Applicability of Refrigerant Release Technology in Room Air Conditioner

نویسندگان

  • Baolong Wang
  • Wenjie Ji
  • Linjun Han
  • Wenxing Shi
  • Baolong WANG
  • Wenjie JI
  • Linjun HAN
  • Wenxing SHI
چکیده

The refrigerant release technology relieves even eliminates the over-compression loss of scroll compressor by bypassing the refrigerant in the compression chamber to the suction pipe under small system pressure ratio conditions. Because the room air conditioner works in mild conditions at most of the time, its seasonal energy performance is expected to be effectively improved by the refrigerant release technology. Accordingly, the effect of refrigerant release on the seasonal performance of the room air conditioner is analyzed and the applicability is evaluated in this paper. The results show that, for the fixed speed air conditioner, the refrigerant release technology decreases 14%~24% and 20%~23% seasonal energy consumption for residential and office building, respectively. The refrigerant release technology has good applicability for the room air conditioner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Experimentation of Roll Bond Evaporator for Room Air Conditioner with R-22 as Refrigerant

The world is looking towards producing products which consume less power without compromising on quality of life. The increase in use of refrigeration and air conditioning appliances are contributing to global warming. The world wide temperatures are shooting up at an increasing rate. This paper presents a design of roll bond evaporator as the heat exchanger to provide cooling in room air condi...

متن کامل

Window Air Conditioner with Orthodox Refrigerants

The system design of window air conditioner does not evolve in one day. Due to the continous efforts are taken by the refrigeration and air conditionging professionals, successful and economic models of window air conditioners are currently used. This paper states about the development of window air conditioner with phase change material and water as refrigerants. Developed air conditioner was ...

متن کامل

Leakage of Mildly Flammable Refrigerants into a Room

The use of chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) has been widely restricted. They have been replaced with hydrofluorocarbons (HFCs) in order to protect the ozone layer. However, the leakage of refrigerant into the air from active or end-of-life air conditioners is a serious environmental issue owing to the high global warming potential (GWP) of HFCs. Therefore, replaci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014