Within-laboratory and between-laboratory variability in the measurement of anti-müllerian hormone determined within an external quality assurance scheme.

نویسندگان

  • Emily Zuvela
  • Melanie Walls
  • Phillip Matson
چکیده

Ten laboratories in an external quality assurance scheme used the same assay to measure anti-müllerian hormone concentration (Beckman Coulter Gen II) and received twenty serum samples distributed over a 15 month period. The mean bias for all results was only -0.089%, but there was large coefficient of repeatability of 38.8% (sample bias ranged from -37.9% to +54.7%). While each laboratory showed good reproducibility, there was a wide range of average values relative to the consensus value from -24.0% to +22.7%. This between-laboratory variability suggests clinicians should use the same laboratory to avoid problems with result interpretation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-4: External Quality Assessment - A Necessity in The Andrology Laboratory

Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...

متن کامل

Reduced anti-Müllerian hormone (AMH) in mares with hemorrhagic anovulatory follicles

Anti-Müllerian hormone (AMH) has been observed to decrease with the development of hemorrhagic anovulatory follicles (HAFs) in mares. Two studies were conducted to evaluate AMH concentration in mares with HAFs compared to seasonally anoestrous and cyclic mares, and to elucidate changes of AMH with the development of luteinised unruptured follicles (LUFs). In study 1, AMH and progesterone were e...

متن کامل

A Comparative Study on Instrumental Precision of Refrigerated and Non-Refrigerated Auto-Analyzers in Order to Improve Quality Assurance in Biochemistry Laboratory

Background and Objective: Quality control is one of the most important components in order to improve quality assurance in laboratories during analytical steps. For this purpose, coefficient of variation plays an important role. Due to the fast improvement in technology, application of inferential statistics for the comparisons ...

متن کامل

ANA IIF Automation: Moving towards Harmonization? Results of a Multicenter Study

Background. Our study aimed to investigate whether the introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis decreases the interlaboratory variability of ANA titer results. Method. Three serum samples were sent to 10 laboratories using the QUANTA-Lyser® in combination with the NOVA View®. Each laboratory performed the ANA IIF analysis 10x in 1 run and ...

متن کامل

External quality assessment for biochemical markers of myocardial damage: an Italian experience.

In 1999 the Centre of Biomedical Research (CRB) in co-operation with the Italian interdisciplinary and intersociety Working Group on Markers of Myocardial Damage proposed a national external quality assurance scheme that was granted in accordance with the UK Clinical Pathology Accreditation Standards in 2001. The scheme, which stresses the importance of educational aspects in quality assurance,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Reproductive biology

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2013