Comparison of two Bayesian methods to detect mode effects between paper-based and computerized adaptive assessments: a preliminary Monte Carlo study

نویسندگان

  • Barth B Riley
  • Adam C Carle
چکیده

BACKGROUND Computerized adaptive testing (CAT) is being applied to health outcome measures developed as paper-and-pencil (P&P) instruments. Differences in how respondents answer items administered by CAT vs. P&P can increase error in CAT-estimated measures if not identified and corrected. METHOD Two methods for detecting item-level mode effects are proposed using Bayesian estimation of posterior distributions of item parameters: (1) a modified robust Z (RZ) test, and (2) 95% credible intervals (CrI) for the CAT-P&P difference in item difficulty. A simulation study was conducted under the following conditions: (1) data-generating model (one- vs. two-parameter IRT model); (2) moderate vs. large DIF sizes; (3) percentage of DIF items (10% vs. 30%), and (4) mean difference in θ estimates across modes of 0 vs. 1 logits. This resulted in a total of 16 conditions with 10 generated datasets per condition. RESULTS Both methods evidenced good to excellent false positive control, with RZ providing better control of false positives and with slightly higher power for CrI, irrespective of measurement model. False positives increased when items were very easy to endorse and when there with mode differences in mean trait level. True positives were predicted by CAT item usage, absolute item difficulty and item discrimination. RZ outperformed CrI, due to better control of false positive DIF. CONCLUSIONS Whereas false positives were well controlled, particularly for RZ, power to detect DIF was suboptimal. Research is needed to examine the robustness of these methods under varying prior assumptions concerning the distribution of item and person parameters and when data fail to conform to prior assumptions. False identification of DIF when items were very easy to endorse is a problem warranting additional investigation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Bayesian Networks Approach to Reliability Analysis of a Launch Vehicle Liquid Propellant Engine

This paper presents an extension of Bayesian networks (BN) applied to reliability analysis of an open gas generator cycle Liquid propellant engine (OGLE) of launch vehicles. There are several methods for system reliability analysis such as RBD, FTA, FMEA, Markov Chains, and etc. But for complex systems such as LV, they are not all efficiently applicable due to failure dependencies between compo...

متن کامل

Comparison of Estimates Using Record Statistics from Lomax Model: Bayesian and Non Bayesian Approaches

This paper address the problem of Bayesian estimation of the parameters, reliability and hazard function in the context of record statistics values from the two-parameter Lomax distribution. The ML and the Bayes estimates based on records are derived for the two unknown parameters and the survival time parameters, reliability and hazard functions. The Bayes estimates are obtained based on conju...

متن کامل

E-Bayesian Estimations of Reliability and Hazard Rate based on Generalized Inverted Exponential Distribution and Type II Censoring

Introduction      This paper is concerned with using the Maximum Likelihood, Bayes and a new method, E-Bayesian, estimations for computing estimates for the unknown parameter, reliability and hazard rate functions of the Generalized Inverted Exponential distribution. The estimates are derived based on a conjugate prior for the unknown parameter. E-Bayesian estimations are obtained based on th...

متن کامل

Attenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study

Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...

متن کامل

Monte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models

Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012