Biomechanical Changes in Disc Pressure and Facet Strain after Lumbar Spinal Arthroplasty with CharitéTM in the Human Cadaveric Spine under Physiologic Compressive Follower Preload.

نویسندگان

  • Jong-Il Choi
  • Se-Hoon Kim
  • Dong-Jun Lim
  • Sung-Kon Ha
  • Sang-Dae Kim
چکیده

AIM Arthroplasty maintains the biomechanical features of a healthy disc, decreases the adjacent segment disease rate, and decreases the accelerated degeneration rate of the neighboring discs in traditional fusion procedures. However, there are only a few reports on adjacent disc pressure (DP) and facet strain (FS) after lumbar arthroplasty under a physiologic compressive preload. MATERIAL AND METHODS Baseline DP and FS measurements were obtained from five intact cadaveric human lumbosacral spines for different modes of motion. DP was measured by inserting pressure transducer needle tips into the L3-L4 and L5-S1 discs. FS gauges were fixed on both sides of the laminae near the L3-L4, L4-L5, and L5-S1 facet joints. After SB Charité < sup > TM < /sup > III implantation at the L4-L5 level, the measurements were repeated at preload and compared with those of the intact spine. RESULTS Under the preload condition, the central DP of the upper disc was decreased during extension and bending, and it significantly increased during rotation (p < 0.05). In the lower disc, the central DP insignificantly decreased during bending and increased during extension and flexion. A statistically significant increase in FS was observed during rotation at the operative facet (p < 0.05). Compared to the intact spine, all FS values were insignificantly decreased during lateral bending but increased during axial rotation. CONCLUSION In an ex-vivo physiologic preload setting, the SB Charité < sup > TM < /sup > III provided relatively inconsistent and sometimes increased DP or FS at the operative and adjacent levels after arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical response of lumbar facet joints under follower preload: a finite element study.

BACKGROUND Facet joints play a significant role in providing stability to the spine and they have been associated with low back pain symptoms and other spinal disorders. The influence of a follower load on biomechanics of facet joints is unknown. A comprehensive research on the biomechanical role of facets may provide insight into facet joint instability and degeneration. METHOD A nonlinear f...

متن کامل

Effect of follower load on motion and stiffness of the human thoracic spine with intact rib cage.

Researchers have reported on the importance of the rib cage in maintaining mechanical stability in the thoracic spine and on the validity of a compressive follower preload. However, dynamic mechanical testing using both the rib cage and follower load has never been studied. An in vitro biomechanical study of human cadaveric thoracic specimens with rib cage intact in lateral bending, flexion/ext...

متن کامل

Facet joint contact pressure is not significantly affected by ProDisc cervical disc arthroplasty in sagittal bending: a single-level cadaveric study.

BACKGROUND CONTEXT Total disc arthroplasty is a motion-preserving spinal procedure that has been investigated for its impact on spinal motions and adjacent-level degeneration. However, the effects of disc arthroplasty on facet joint biomechanics remain undefined despite the critical role of these posterior elements on guiding and limiting spinal motion. PURPOSE The goal was to measure the pre...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study

BACKGROUND Finite element analysis results will show significant differences if the model used is performed under various material properties, geometries, loading modes or other conditions. This study adopted an FE model, taking into account the possible asymmetry inherently existing in the spine with respect to the sagittal plane, with a more geometrically realistic outline to analyze and comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 2017