Collision indicator charts for gantry‐couch position combinations for Siemens ONCOR and Elekta Infinity linacs

نویسندگان

  • Stewart J. Becker
  • Wes Culberson
  • Ryan T. Flynn
چکیده

Noncoplanar radiation fields from a linear accelerator can be used to deliver radiation dose distributions that are superior to those delivered using coplanar radiation fields. Noncoplanar radiation field arrangements are especially valuable when delivering stereotactic body radiation therapy (SBRT). Noncoplanar radiation fields, however, are geometrically more challenging to deliver than coplanar radiation fields, and are associated with a greater risk of collisions between the gantry, treatment couch, and patient. Knowledge of which treatment couch offset, treatment couch angle, and gantry angle combinations provide a collision-free radiotherapy delivery is useful in the treatment planning process, as the risk of requiring replanning due to improperly selected treatment parameters can be minimized. Such tables are by default specific to the linear accelerator make and model used for treatment. In this work a set of plots is presented indicating which combination of treatment couch lateral offsets (-10 cm to 10 cm), couch angles (270° to 90°), and gantry angles (0° to 360°), will result in collision-free radiation delivery using Siemens ONCOR linear accelerators equipped with a 160-leaf multileaf collimator and a 550 TxT treatment table, and a Elekta Infinity linear accelerator with an MLCi2 and Elekta iBEAM evo Couchtop EP. The patient was assumed to have a width of 50 cm and a height of 25 cm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collision indicator charts for gantry‐couch position combinations for Varian linacs

The use of non-coplanar radiation fields can potentially lead to collisions between the gantry and the couch or patient. The collisions are often not realized until the plan is finished and the fields are checked on the machine, or even later when the patient is already on the table. This paper presents an easy method of gauging if a collision is likely between the gantry and couch or patient d...

متن کامل

Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators.

Neutrons are a by-product of high-energy x-ray radiation therapy (threshold for [gamma,n] reactions in high-Z material -7 MeV). Neutron production varies depending on photon beam energy as well as on the manufacturer of the accelerator. Neutron production from modern linear accelerators (linacs) has not been extensively compared, particularly in terms of the differences in the strategies that v...

متن کامل

Fast IMRT by increasing the beam number and reducing the number of segments

PURPOSE The purpose of this work is to develop fast deliverable step and shoot IMRT technique. A reduction in the number of segments should theoretically be possible, whilst simultaneously maintaining plan quality, provided that the reduction is accompanied by an increased number of gantry angles. A benefit of this method is that the segment shaping could be performed during gantry motion, ther...

متن کامل

Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device

BACKGROUND In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evalu...

متن کامل

AbstractID: 9678 Title: An analytical approach to prevent gantry-couch collision for linac-based radiosurgery

ID: 9678 Title: An analytical approach to prevent gantry-couch collision for linac-based radiosurgery Gantry-couch collision is a serious concern for the treatment planning of the linac-based stereotactic radiosurgery (SRS). The ability to detect collision at the planning time removes the need for backup plans and preserves the useful beam angles that would be deemed unsafe and discarded otherw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013