CARDIOVASCULAR MEDICINE Incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias in high risk coronary patients and prophylactic implantation of a defibrillator

نویسنده

  • M Borggrefe
چکیده

Objectives: To assess the incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias after implantable cardioverter-defibrillator (ICD) implantation for primary prevention. Design: Prospective observational study. Patients: 41 consecutive patients, who fulfilled MADIT (multicenter automatic defibrillator implantation trial) I criteria, except for suppressibility by procainamide, and who received a prophylactic ICD. Interventions: Subpectoral implantation of an ICD. Main outcome measures: Incidence of ventricular tachyarrhythmias and their electrophysiological characteristics with respect to timing of the arrhythmia, tachyarrhythmia cycle length, mode of termination, and clinical relevance. Results: During a mean (SD) follow up of 30 (21) months 18 of 41 (43.9%) patients experienced 142 appropriate ICD treatments. The mean (SD) time to first event was 9.6 (15.1) months. One patient had ventricular fibrillation (VF), 12 patients ventricular tachycardia (VT), and five both VT and VF. The mean (SD) cycle length of monomorphic VT was 306 (42) ms. Of 142 episodes, 117 (82.3%) were terminated by antitachycardia pacing and another 25 (17.6%) by ICD discharges. Cumulative survival of hypothetical death, defined as treated VT with a cycle length , 260 ms or VF, was 83.2% after one year and 78.4% after two years. Conclusions: Patients with a left ventricular ejection fraction , 35%, a history of myocardial infarction, non-sustained VT, and inducible VT/VF are at high risk of VT/VF early after implantation. Therefore, implantation of a tiered treatment defibrillator seems to be justified.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias in high risk coronary patients and prophylactic implantation of a defibrillator.

OBJECTIVES To assess the incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias after implantable cardioverter-defibrillator (ICD) implantation for primary prevention. DESIGN Prospective observational study. PATIENTS 41 consecutive patients, who fulfilled MADIT (multicenter automatic defibrillator implantation trial) I criteria, except for suppressibi...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Effect of gallic acid on electrophysiological properties and ventricular arrhythmia following chemical-induced arrhythmia in rat

Objective(s): Ventricular arrhythmias including ventricular tachycardia (VT) and ventricular fibrillation (VF) are the most important causes of mortality rate. Gallic acid (GA) has beneficial effects on cardiovascular diseases. The aim of this study was to evaluate the effects of GA on electrophysiological parameters such as QRS complex, heart rate (HR), PR interval pa...

متن کامل

A Randomized Double Blind Placebo Controlled Trial Examining the Effects of Pentoxifylline on Contrast Induced Nephropathy Reduction after Percutaneous Coronary Intervention in High Risk Candidates

Contrast-induced nephropathy (CIN) (known as contrast-induced acute kidney injury) occurs as a result of acute worsening of renal function following a procedure with administration of iodine contrasts agent and remains a substantial concern in clinical practices. The purpose of this study is to investigate the preventive effect of Pentoxifylline supplementation on reduction of CIN occurrence af...

متن کامل

A Randomized Double Blind Placebo Controlled Trial Examining the Effects of Pentoxifylline on Contrast Induced Nephropathy Reduction after Percutaneous Coronary Intervention in High Risk Candidates

Contrast-induced nephropathy (CIN) (known as contrast-induced acute kidney injury) occurs as a result of acute worsening of renal function following a procedure with administration of iodine contrasts agent and remains a substantial concern in clinical practices. The purpose of this study is to investigate the preventive effect of Pentoxifylline supplementation on reduction of CIN occurrence af...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004