Quality assessment of patients’ self-monitoring of blood glucose in community pharmacies

نویسندگان

  • Reidun L. S. Kjome
  • Anne G. Granas
  • Kari Nerhus
  • Sverre Sandberg
چکیده

OBJECTIVE To evaluate diabetes patients' self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. METHODS The results of patient blood glucose measurements were compared to the results obtained with HemoCue Glucose 201(+) by pharmacy employees in 16 Norwegian community pharmacies. Patient performance was monitored using an eight item checklist. Patients whose blood glucose measurements differed from pharmacy measurements by more than 20% were instructed in the correct use of their glucometer. The patients then re-measured their blood glucose. If the results were still outside the set limits, the control procedure was repeated with a new lot of glucometer strips, and then with a new glucometer. The patients returned for a follow-up visit after three months. RESULTS During the first visit, 5% of the 338 patients had measurements that deviated from pharmacy blood glucose values by more than 20% and user errors were observed for 50% of the patients. At the second visit, there was no significant change in the analytical quality of patient measurements, but the percentage of patients who made user errors had decreased to 29% (p < 0.001). Eighty-five percent of the patients reported that they used their blood glucose results to adjust medication, exercise or meals. Fifty-one percent of the patients reported a greater trust in their measurements after the second visit. Eighty percent of patients wished to have their measurements assessed yearly. Of these patients, 83% preferred to have the assessment done at the community pharmacy. CONCLUSION A community pharmacy-based quality assessment procedure of patients' self monitoring of blood glucose significantly reduced the number of user errors. The analytical quality of the patients' measurements was good and did not improve further during the study. The high analytical quality might be explained by a selection bias of participating patients. Patients also reported increased confidence in their blood glucose measurements after their measurements had been assessed at the pharmacy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Community pharmacy-based intervention to improve self-monitoring of blood glucose in type 2 diabetic patients

UNLABELLED Self-monitoring of blood glucose (SMBG) is clearly correlated with increased life expectancy and quality of life in type 2 diabetic patients. OBJECTIVE The objective of our study was to record and assess the errors patients make in preparing, performing, and processing self-monitoring of blood glucose (SMBG). Furthermore, the study aimed to determine to what extent a single standar...

متن کامل

The asheville project: short-term outcomes of a community pharmacy diabetes care program.

OBJECTIVES To assess short-term clinical, economic, and humanistic outcomes of pharmaceutical care services (PCS) for patients with diabetes in community pharmacies. DESIGN Intention-to-treat, pre-post cohort-with-comparison group study. SETTING Twelve community pharmacies in Asheville, N.C. PATIENTS AND OTHER PARTICIPANTS Eighty-five patients with diabetes who were employees, dependents, or re...

متن کامل

تأثیر مداخله آموزشی مبتنی بر الگوی مراقبت پیگیر بر خودپایشی قند خون بیماران دیابتی نوع 2

Background and Aim: Appropriate control of blood sugar delays the onset and progression of diabetes mellitus (DM) complications. Nurses have a decisive role in the education of self-care behaviors to diabetic patients, including self-monitoring of blood glucose. The current study aimed at assessing the effect of educational intervention based on continuous care model on self-monitoring of blood...

متن کامل

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

Improving adherence to lipid-lowering therapy in a community pharmacy intervention program: a cost-effectiveness analysis.

BACKGROUND Pharmaceutical care in community pharmacies has been shown to improve adherence to chronic therapies. Long-term impact on clinical outcomes or medical cost savings, however, remains understudied.  OBJECTIVE To estimate the cost-effectiveness of a pharmaceutical care intervention program in Dutch community pharmacies that improved patients' adherence to lipid-lowering therapy.  ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2010