The effect of beam arrangements and the impact of non‐coplanar beams on the treatment planning of stereotactic ablative radiation therapy for early stage lung cancer

نویسندگان

  • Rhys Fitzgerald
  • Rebecca Owen
  • Tamara Barry
  • Cathy Hargrave
  • David Pryor
  • Anne Bernard
  • Margot Lehman
  • Tao Mai
  • Andrew Fielding
چکیده

INTRODUCTION The aim of this study was to compare various coplanar and non-coplanar 3-dimensional conformal radiation therapy (3DCRT) beam arrangements for the delivery of stereotactic ablative radiation therapy (SABR) to patients with early stage lung cancer, based on the dosimetric criteria from the Radiation Therapy Oncology Group (RTOG) 1021 protocol. METHODS Ten medically inoperable lung cancer patients eligible for SABR were re-planned using three different coplanar and three different non-coplanar beam arrangements. The plans were compared by assessing planning target volume (PTV) coverage, doses to normal tissues, the high-dose conformity (conformity index) and intermediate dose spillage as defined by the D2cm, (the dose at any point 2 cm away from the PTV), and the R50% (the ratio of the volume of half the prescription dose to the volume of the PTV). RESULTS Sixty plans in total were assessed. Mean PTV coverage with the prescription isodose was similar between coplanar (95.14%) and non-coplanar (95.26%) techniques (P = 0.47). There was significant difference between all coplanar and all non-coplanar fields for the R50% (P < 0.0001) but none for the D2cm (P = 0.19). The seven and nine field beam arrangements with two non-coplanar fields had less unacceptable protocol deviations (10 and 7) than the seven and nine field plans with only coplanar fields (13 and 8). The 13 field coplanar fields did not improve protocol compliance with eight unacceptable deviations. The 10 field non-coplanar beam arrangement achieved best compliance with the RTOG 1021 dose criteria with only one unacceptable deviation (maximum rib dose). CONCLUSION A 3DCRT planning technique using 10 fields with ≥6 non-coplanar beams best satisfied high and intermediate dose constraints stipulated in the RTOG 1021 trial. Further investigations are required to determine if minor protocol deviations should be balanced against efficiency with the extended treatment times required to deliver non-coplanar fields and if treatment times can be improved using novel intensity modulated techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

Evaluation of Accuracy and Quality assurance of external beam therapy with photons

Introduction: Receiving exact dose by the patients is vital in radiotherapy. In radiation therapy, the dosimetry of radiations is too important because of successful radiation inquires for delivering the exact dose to the target volume. This study is to evaluate the tolerances and the accuracy of calculated dose of photon beams in the treatment software system. The TECDOC1583 p...

متن کامل

A comparison of three different VMAT techniques for the delivery of lung stereotactic ablative radiation therapy.

INTRODUCTION The purpose of this study was to investigate coplanar and non-coplanar volumetric modulated arc therapy (VMAT) delivery techniques for stereotactic ablative radiation therapy (SABR) to the lung. METHODS For ten patients who had already completed a course of radiation therapy for early stage lung cancer, three new SABR treatment plans were created using (1) a coplanar full arc (FA...

متن کامل

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Physicians considering stereotactic ablative body radiation therapy (SBRT) for the treatment of extracranial cancer targets must be aware of the sizeable risks for normal tissue injury and the hazards of physical tumor miss. A first-of-its-kind SBRT platform achieves high-precision ablative radiation treatment through a combination of versatile real-time imaging solutions and sophisticated tumo...

متن کامل

Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 63  شماره 

صفحات  -

تاریخ انتشار 2016