Evaluating laser-driven Bremsstrahlung radiation sources for imaging and analysis of nuclear waste packages.

نویسندگان

  • Christopher P Jones
  • Ceri M Brenner
  • Camilla A Stitt
  • Chris Armstrong
  • Dean R Rusby
  • Seyed R Mirfayzi
  • Lucy A Wilson
  • Aarón Alejo
  • Hamad Ahmed
  • Ric Allott
  • Nicholas M H Butler
  • Robert J Clarke
  • David Haddock
  • Cristina Hernandez-Gomez
  • Adam Higginson
  • Christopher Murphy
  • Margaret Notley
  • Charilaos Paraskevoulakos
  • John Jowsey
  • Paul McKenna
  • David Neely
  • Satya Kar
  • Thomas B Scott
چکیده

A small scale sample nuclear waste package, consisting of a 28mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500keV), with a source size of <0.5mm. BAS-TR and BAS-SR image plates were used for image capture, alongside a newly developed Thalium doped Caesium Iodide scintillator-based detector coupled to CCD chips. The uranium penny was clearly resolved to sub-mm accuracy over a 30cm(2) scan area from a single shot acquisition. In addition, neutron generation was demonstrated in situ with the X-ray beam, with a single shot, thus demonstrating the potential for multi-modal criticality testing of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subcutaneous Extravasation of Sr-89: Usefulness of Bremsstrahlung Imaging in Confirming Sr-89 Extravasation and in the Decision Making for the Choice of Treatment Strategies for Local Radiation Injuries Caused by Sr-89 Extravasation

A male patient in his 20s presented at our clinic with pain caused by bone metastases of the primitive neuroectodermal tumor, and Sr-89 was administrated to palliate the pain. After receiving the injection, the patient complained of a slight burning pain at the catheterized area. Slight reddening and small circular swelling (diameter, 0.5 cm) were observed at the catheterized area. Sr-89 extrav...

متن کامل

ارزیابی کولیماتورهای لایه‌ای در تصویربرداری تابش ترمزی حین رادیو دارو درمانی با فسفر-32

Background and purpose: Imaging which is used in nuclear medicine is done using emit gamma rays whereas therapy in nuclear medicine is performed by applying radionuclide’s which emit beta radiation. Using Bremsstrahlung is a new field which is recently introduced in imaging. In the Bremsstrahlung imaging, collimator design should not be based on energy peak and whole energy spectrum should be c...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

Optimization of Bremsstrahlung imaging in Yttrium internal radiation therapy

Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...

متن کامل

Bremsstrahlung imaging from the liver using the Monte Carlo simulation

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of hazardous materials

دوره 318  شماره 

صفحات  -

تاریخ انتشار 2016