Calibration and Standards in Flow Measurement
نویسنده
چکیده
Calibration is defined as follows: ‘The set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system and the corresponding values realized by standards.’ It is important to recognize at the outset the definition of a ‘calibration’ and to note that the ‘comparison’ applies only to the conditions at the time of the calibration. The purpose of calibration is to increase the confidence in the reading obtained from the flowmeter in service. Standards for flow measurement are based on a comparison of the quantity of fluid passed, or passing, through the flowmeter with the quantity measured by the standard. Standards can be based on the measurement of mass or volume. The required mass or volume quantity can be calculated from the measured quantity from a knowledge of the fluid density at the test flowmeter. Standards may be static or dynamic, and this choice is made on the basis of the output and end use of the flowmeter. Some flowmeters are used to measure quantity and have a fast response time; others are designed to measure flow rate and have a slow response time. Calibration of a flowmeter should cover a significant flow-rate range for the flowmeter and establish a performance across that range. A ‘standard’ for flow calibration should replicate as closely as practicable the conditions under which the flowmeter will be used. Full replication is impossible, and the key to success is to be as close as practicable, and to recognize the nature and performance of the flowmeter type being tested. The factors that should be addressed are the fluid viscosity, the installation effects due to bends and fittings, temperature, and pressure. The standard should also have a defined traceability and uncertainty chosen to match the expectation of the final measurement. The choice of standard must also recognize the dynamic performance of the flowmeter and the nature and resolution of the output. As a calibration is a comparison, the quantity measured by the standard must match the quantity measured by the flowmeter and this must take cognizance of the resolution of the flowmeter. A flowmeter used to measure very large quantities of fluid over a long period of time may not have a resolution suitable for measuring the smaller quantities measured by a standard. The result of a flowmeter calibration will normally provide two related figures: one related to the flow rate and the other as a performance indicator. Flow rate will be expressed as mass per unit time, volume per unit time, Reynolds number, or some other flow rate–related measure. The performance indicator relates the expected performance of the meter to the measured performance. Examples of performance indicators are K-factor, error, and meter factor.
منابع مشابه
Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملRadon monitor calibration using NIST radon emanation standards: steady flow method.
The National Institute of Standards and Technology (NIST) polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards (old SRM 4968 and new SRMs 4971, 4972, and 4973) provide precise radon emanation rate, certified to a high degree of accuracy (approximately to 2%). Two new SRM 4973 standards containing totally 1036 Bq (0.028 microCi) of 226Ra, emanate 0.114 Bq (3.08 pCi) of 222Rn per min....
متن کاملThe Characterization of a Piston Displacement-Type Flowmeter Calibration Facility and the Calibration and Use of Pulsed Output Type Flowmeters
Critical measurement performance of fluid flowmeters requires proper and quantified verification data. These data should be generated using calibration and traceability techniques established for these verification purposes. In these calibration techniques, the calibration facility should be well-characterized and its components and performance properly traced to pertinent higher standards. The...
متن کاملCalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...
متن کاملGas Flow Metering Using the PSO Optimized Interval Type- 2 Fuzzy Neural Network
Orifice flow meter is one of the most common devices in industry which is used for measuring the gas flow. This system includes an orifice plate, temperature and pressure transmitters, and a flow computer. The flow computer is used for collecting information related to temperature, pressure, and their differences under various conditions. Also the flow computer can calculate the flow rate of ga...