Costs and consequences of automated algorithms versus manual grading for the detection of referable diabetic retinopathy.

نویسندگان

  • G S Scotland
  • P McNamee
  • A D Fleming
  • K A Goatman
  • S Philip
  • G J Prescott
  • P F Sharp
  • G J Williams
  • W Wykes
  • G P Leese
  • J A Olson
چکیده

AIMS To assess the cost-effectiveness of an improved automated grading algorithm for diabetic retinopathy against a previously described algorithm, and in comparison with manual grading. METHODS Efficacy of the alternative algorithms was assessed using a reference graded set of images from three screening centres in Scotland (1253 cases with observable/referable retinopathy and 6333 individuals with mild or no retinopathy). Screening outcomes and grading and diagnosis costs were modelled for a cohort of 180 000 people, with prevalence of referable retinopathy at 4%. Algorithm (b), which combines image quality assessment with detection algorithms for microaneurysms (MA), blot haemorrhages and exudates, was compared with a simpler algorithm (a) (using image quality assessment and MA/dot haemorrhage (DH) detection), and the current practice of manual grading. RESULTS Compared with algorithm (a), algorithm (b) would identify an additional 113 cases of referable retinopathy for an incremental cost of pound 68 per additional case. Compared with manual grading, automated grading would be expected to identify between 54 and 123 fewer referable cases, for a grading cost saving between pound 3834 and pound 1727 per case missed. Extrapolation modelling over a 20-year time horizon suggests manual grading would cost between pound 25,676 and pound 267,115 per additional quality adjusted life year gained. CONCLUSIONS Algorithm (b) is more cost-effective than the algorithm based on quality assessment and MA/DH detection. With respect to the value of introducing automated detection systems into screening programmes, automated grading operates within the recommended national standards in Scotland and is likely to be considered a cost-effective alternative to manual disease/no disease grading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of haemorrhage and exudate detection in automated grading of diabetic retinopathy.

BACKGROUND/AIMS Automated grading has the potential to improve the efficiency of diabetic retinopathy screening services. While disease/no disease grading can be performed using only microaneurysm detection and image-quality assessment, automated recognition of other types of lesions may be advantageous. This study investigated whether inclusion of automated recognition of exudates and haemorrh...

متن کامل

Assessment of Automated Disease Detection in Diabetic Retinopathy Screening Using Two-Field Photography

AIM To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. METHODS Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of ...

متن کامل

Automated grading for diabetic retinopathy: a large-scale audit using arbitration by clinical experts.

BACKGROUND/AIMS Automated grading software has the potential to reduce the manual grading workload within diabetic retinopathy screening programmes. This audit was undertaken at the request of Scotland's National Diabetic Retinopathy Screening Collaborative to assess whether the introduction of automated grading software into the national screening programme would be safe, robust and effective....

متن کامل

Validation of automated screening for referable diabetic retinopathy with the IDx‐DR device in the Hoorn Diabetes Care System

PURPOSE To increase the efficiency of retinal image grading, algorithms for automated grading have been developed, such as the IDx-DR 2.0 device. We aimed to determine the ability of this device, incorporated in clinical work flow, to detect retinopathy in persons with type 2 diabetes. METHODS Retinal images of persons treated by the Hoorn Diabetes Care System (DCS) were graded by the IDx-DR ...

متن کامل

Diagnosis of Diabetic Retinopathy Using Processing of Fundus Images and Morphological Techniques

Introduction: Diabetic retinopathy is the damaging effect of diabetes on retinal blood vessels that can cause blindness when diagnosed late. Microaneurysms are early signs of the disease that their early diagnosis promotes timely treatment and prevents disease progression. Since this disease is asymptomatic and can only be detected by ophthalmologists, diabetic patients should be tested regular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 94 6  شماره 

صفحات  -