Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals.

نویسندگان

  • Sung-Yeop You
  • Kwang-Shik Bae
  • Seung-Ho Baek
  • Kee-Yeon Kum
  • Won-Jun Shon
  • Woocheol Lee
چکیده

INTRODUCTION The purpose of this study was to examine the lifespan of one nickel-titanium (NiTi) rotary file when used in reciprocating motion and to compare the time required for its preparation of a curved root canal using both reciprocating and continuous motion. METHODS One hundred twenty curved canals from 60 extracted maxillary and mandibular molars were selected for measuring the mean number of uses. Each canal was prepared with reciprocating motion until the ProTaper F2 single file (Dentsply Maillefer, Ballaigues, Switzerland) reached the working length. One file was used until it was fractured. Another 60 canals were divided into two groups. 30 canals in the continuous rotation motion (CM) group were prepared using continuous rotation following the sequence of ProTaper files, whereas the canals in the reciprocating motion (RM) group (n = 30) were prepared with reciprocating motion with the sole use of the ProTaper F2. The total root canal preparation time was measured until the F2 file finally reached the working length in both groups. RESULTS A total of 11 files were used in the preparation of 120 curved root canals. The average lifespan of one F2 file was 10.60 ± 4.35 canals with the longest lifespan of 21 canals. The total time for canal preparation was 46.42 ± 18.12 seconds and 21.15 ± 6.70 seconds in the CM and RM groups, respectively. There was a statistically significant difference between the groups (p < 0.01). CONCLUSION Within the limitation of this study, one F2 file can be safely used to the working length of curved canals at least six times under reciprocating motion. Reciprocating preparation with only one F2 file was much faster than root canal instrumentation with continuous rotation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of CM-Wire, M-Wire, and Nickel-Titanium Instruments for Removing Filling Material from Curved Root Canals: A Micro-Computed Tomography Study.

INTRODUCTION The aim of this ex vivo study was to evaluate the removal of filling material after using CM-wire, M-wire, and nickel-titanium instruments in both reciprocating and rotary motions in curved canals. METHODS Thirty maxillary lateral incisors were divided into 9 groups according to retreatment procedures: Reciproc R25 followed by Mtwo 40/.04 and ProDesign Logic 50/.01 files; ProDesi...

متن کامل

Root Canal Surface Strain and Canal Center Transportation Induced by 3 Different Nickel-Titanium Rotary Instrument Systems.

INTRODUCTION Root canal anatomy and canal preparation instruments affect the outcome of endodontic treatment. The purpose of this study was to determine the root surface strain (SS) generated and the extent of canal center transportation during canal shaping using 3 different nickel-titanium instruments. METHODS Simulated root canals in resin blocks (n = 10 per group) were prepared using adap...

متن کامل

Single file niti - rotary systems

IJMDS ● www.ijmds.org ● January 2015; 4(1) 701 Review Article Single file niti-rotary systems Kumar SR, Gade V ABSTRACT The cleaning and shaping of root canals is a major step in root canal treatment procedure, which aims at removal of all the tissue debris from the root canal space while removing the inner layers of root canal dentin. With Nickel titanium (NiTi) rotary instruments this goal is...

متن کامل

Evaluation of Apical Extrusion of Debris and Irrigant Using Two New Reciprocating and One Continuous Rotation Single File Systems

OBJECTIVE Apical extrusion of debris and irrigants during cleaning and shaping of the root canal is one of the main causes of periapical inflammation and postoperative flare-ups. The purpose of this study was to quantitatively measure the amount of debris and irrigants extruded apically in single rooted canals using two reciprocating and one rotary single file nickel-titanium instrumentation sy...

متن کامل

Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

INTRODUCTION The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. METHODS Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 36 12  شماره 

صفحات  -

تاریخ انتشار 2010