Evaluation of blood volume measurement techniques.
نویسندگان
چکیده
OUR STUDIES on the seeming loss of plasma from the circulation after transfusion and the mobilization of plasma often seen after hemorrhage or drug infusions have been handicapped by a large variation in measured responses between animals. Conversations with other workers on blood volume regulation have indicated that such variability is not uncommon. The necessity of using large groups of animals to test the effect of any experimental change makes for tedious research. It also raises the question as to the quantitative accuracy of the techniques used for measuring blood volume. We have, therefore, made several consecutive injections of T 1824 and Cr-tagged red cells in the same dogs to measure the ability of the two techniques to reproduce the same volume. This was then followed by a study of the ability of the two to follow known reductions in blood volume produced by stepwise hemorrhage. We have shown that after an injection of tagged cells into dogs under morphine-sodium pentobarbital anesthesia, the blood activity level falls to a fairly stable value in about 10 minutes in splenectomized animals and in 20 to 30 minutes in intact dogs. Variations of individual samples, when corrected for any hematocrit change, about the average plateau value have a standard deviation of 3 per cent. Since the hematocrit technique shows a standard deviation of 2 per cent, errors attributable to an uneven distribution of tagged cells in the circulation would appear to be small. Injected T 1824 does not, of course, reach a stable concentration after mixing is completed, but continues to disappear through the capillary membranes at what has been claimed to be an exponential rate.' If the
منابع مشابه
Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملIncreasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method
Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملBlood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation research
دوره 9 شماره
صفحات -
تاریخ انتشار 1961