End-tidal CO2 monitoring during anesthesia.

نویسنده

  • C A Griffis
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تأثیر تهویه با حجم‌های جاری متفاوت و تهویه دقیقه‌ای ثابت بر روی دی‌اکسید کربن انتهای بازدمی

Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study  to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2  and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...

متن کامل

Transcutaneous PCO2 monitoring during laparoscopic cholecystectomy in pregnancy.

PURPOSE Respiratory acidosis during carbon dioxide (CO2) insufflation has been suggested as a cause of spontaneous abortion and preterm labour following laparoscopic cholecystectomy during pregnancy. Capnography may not be adequate as a guide to adjust pulmonary ventilation during laparoscopic surgery and hence arterial carbon dioxide (PaCO2) monitoring has been recommended. We report the feasi...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

End-tidal carbon dioxide monitoring in the detection of anesthesia-related critical incidents.

A prospective study was undertaken in an effort to determine the usefulness of the end-tidal carbon dioxide monitor in detecting anesthesia-related critical incidents. The critical incident technique was employed in the evaluation of 2,334 anesthetics. Anesthesia providers completed a critical incident questionnaire following each anesthetic. All questionnaires were analyzed for the occurrence ...

متن کامل

Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.

OBJECTIVE To assess the accuracy of measurements of end tidal carbon dioxide (CO2) during neonatal transport compared with arterial and transcutaneous measurements. DESIGN Paired end tidal and transcutaneous CO2 recordings were taken frequently during road transport of 21 ventilated neonates. The first paired CO2 values were compared with an arterial blood gas. The differences between arteria...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AANA journal

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 1986