Clinical evaluation of a computer simulated prediction model of contrast enhancement of the liver in spiral CT.
نویسندگان
چکیده
OBJECTIVE A software program was developed simulating a compartmental model of blood circulation based on differential equations. The aim of this study was to compare software-simulated levels of hepatic enhancement with the true values in patients and to test how many patients reach the simulated hepatic enhancement level. METHODS As software program the CT application software carebolus 2 (Siemens, Forchheim, Germany) was used. Hepatic contrast-enhancement curves were simulated prior to CT examinations to evaluate a patient specific time delay after contrast application. At the time delay, when the simulation curve showed an enhancement threshold of 40 Hounsfield Units (HU), the CT spiral scan was started applying 120 ml contrast media with 2 ml/s. The simulated curves were compared with the empiric curves of each patient. RESULTS 25 of 28 patients (89%) achieved 40 HU. The mean enhancement of empiric patients curves was 46.32 +/- 11.9 HU, the mean simulated enhancement was 46.62 +/- 4.3 HU S.D. (P= 0.48). 4.4 values per patient liver could be compared with the simulation curve (122 points for 28 patients): 50% of the patient curves were within a range of 5 HU compared with the simulation curve. CONCLUSION Software simulation of contrast enhancement curves of the liver is a feasible and valuable method to predict individual liver enhancement curves. Improvements concerning the integration of cardiovascular parameters and preexisting liver parenchymal diseases into the simulation software have to be arranged.
منابع مشابه
FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT
Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a comb...
متن کاملDensity-Based Histogram Partitioning and Local Equalization for Contrast Enhancement of Images
Histogram Equalization technique is one of the basic methods in image contrast enhancement. Using this method, in the case of images with uniform gray levels (with narrow histogram), causes loss of image detail and the natural look of the image. To overcome this problem and to have a better image contrast enhancement, a new two-step method was proposed. In the first step, the image histogram is...
متن کاملHeat transfer enhancement in a spiral plate heat exchanger model using continuous rods
This study presents an innovative and simple way to increase the rate of heat transfer in a spiral plate heat exchanger model. Several circular cross-section rods, as continuous vortex generators, have been inserted within the spiral plate heat exchanger in the cross-stream plane. The vortex generators are located at various azimuth angles of α=30◦, 60◦, 90◦, and 120◦ with non-dimensional diame...
متن کاملPseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm
Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...
متن کاملUltrasonography and computer tomography evaluation of hepatocellular carcinoma with cytohistopathological correlation.
The prevalence of hepatocellular carcinoma (HCC) in Bangladesh is 35% among all liver diseases. Sonographic examinations were performed for the evaluation of 38 cases of HCC; then, CT examinations were done of these cases subsequently. Expert opinion was taken in each case for both modalities. Age, sex, clinical features, location of the hepatic lesion, multiplicity, echo-character, CT density,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of radiology
دوره 51 1 شماره
صفحات -
تاریخ انتشار 2004