Contrasting effects of static and pulsatile pressure on carotid baroreceptor activity in dogs.

نویسندگان

  • M W Chapleau
  • F M Abboud
چکیده

The purpose of this study was to contrast the effects of static and pulsatile pressure on carotid baroreceptor activity over a wide range of mean arterial pressure. Static and pulsatile pressure were applied to the isolated carotid sinus of dogs anesthetized with chloralose. Recordings were obtained from single baroreceptor units as well as from the whole sinus nerve or a large strand of the nerve. Three observations are reported. First, in single units the pulsatile pressure threshold, which averaged 48 +/- 8 (SEM) mm Hg, was far below the static pressure threshold, which averaged 79 +/- 8 mm Hg (p less than 0.05, n = 15). Thus, pulsatility decreased the threshold by an average of 31 mm Hg in contrast to the minimal or lack of decrease in threshold reported by others in aortic baroreceptors. Second, at moderate arterial pressures a shift from static to pulsatile pressure caused a decrease in single and multiple unit activities. In single units, the decrease approximated 15% (from 42.0 +/- 2.1 to 35.5 +/- 1.9 spikes/sec, p less than 0.05, n = 25). In all units, there was no diastolic nerve activity ("silence") when diastolic pressure was 1 to 10 mm Hg above static pressure threshold; 80% of the units exhibited "diastolic silence" when diastolic pressure was 20-30 mm Hg above threshold and 40% of the units showed silence at diastolic pressures 40-50 mm Hg above threshold. In whole nerve recordings, pulsatility increased activity from 57 +/- 15 to 142 +/- 29 spikes/sec (p less than 0.05) at low mean arterial pressures (50 and 75 mm Hg), as expected from the reduction in pressure threshold noted in single units, and decreased activity by approximately 15% (from 373 +/- 69 to 320 +/- 55 spikes/sec, p less than 0.05, n = 9) at mean arterial pressures of 125 and 150 mm Hg. This decrease in activity with a shift from static to pulsatile pressure at moderate arterial pressures has not been reported previously. Third, the static pressure-activity curve was sigmoid, and its gain peaked sharply at 75-100 mm Hg; in contrast, the pulsatile pressure-activity curve was linear between 25 and 150 mm Hg, and its maximum gain was half the maximum gain during static pressure. These differences between the static pressure-activity curve and the pulsatile pressure-activity curve were noted during both increases and decreases in carotid sinus pressure; both curves exhibited some hysteresis during the decreases in pressure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determinants of sensitization of carotid baroreceptors by pulsatile pressure in dogs.

The threshold pressure of single baroreceptor units is decreased after compared with before exposure to pulsatile pressure according to previous studies in our laboratory. The purpose of the present study is to characterize the determinants of sensitization of arterial baroreceptors by pulsatile pressure. Carotid sinus nerve activity was recorded in dogs anesthetized with chloralose. Two indexe...

متن کامل

Coarctation of the aorta and baroreceptor resetting. A study of carotid baroreceptor stimulus-response characteristics before and after surgical repair in the dog.

We studied baroreceptor function in dogs before and after surgical repair of coarctation of the aorta by direct recording of multifiber carotid sinus (CS) nerve activity (NA) during alteration of pulsatile arterial pressure with systemic phenylephrine and nitroprusside, and during static pressure changes using a CS pouch preparation. Coarctation was induced by banding the proximal thoracic aort...

متن کامل

Prevention or attenuation of baroreceptor resetting by pulsatility during elevated pressure.

Acute static elevation of arterial pressure increases the pressure threshold for activation of baroreceptors (acute resetting). The purpose of this study was to test the hypothesis that pulsatility during acute elevation of pressure modifies this acute resetting. Activity was recorded in 21 single baroreceptor units from the isolated carotid sinuses of dogs anesthetized with chloralose. Single-...

متن کامل

1294 Carotid Sinus Baroreceptor Reflex in Dogs With Experimental Heart Failure

We have previously demonstrated a decrease in baroreceptor discharge sensitivity in dogs with experimental heart failure. In the present study, we determined the sensitivity of the carotid sinus baroreceptor reflex in dogs with pacing-induced heart failure. The carotid sinus baroreceptor reflex sensitivity was determined by pressurizing one carotid sinus with all other baroreceptor and cardiopu...

متن کامل

Carotid sinus baroreceptor reflex in dogs with experimental heart failure.

We have previously demonstrated a decrease in baroreceptor discharge sensitivity in dogs with experimental heart failure. In the present study, we determined the sensitivity of the carotid sinus baroreceptor reflex in dogs with pacing-induced heart failure. The carotid sinus baroreceptor reflex sensitivity was determined by pressurizing one carotid sinus with all other baroreceptor and cardiopu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 61 5  شماره 

صفحات  -

تاریخ انتشار 1987