Is there a fundamental upper limit for the significance I/σ(I) of observations from X-ray and neutron diffraction experiments?

نویسندگان

  • Julian Henn
  • Kathrin Meindl
چکیده

The answer is yes. A fundamental limit exists, which is not strongly applicable to individual reflections but to a sufficiently large set of reflections such as any set for structure determination. The limit originates from Poisson statistics which gives a minimum (average) error. The proposed limit of significance and a proposed decrease in significance due to data processing are also tested by monitoring W = / for raw and for Bragg data. Since Poisson statistics are the lower limit for the experimental standard uncertainties, it is expected that W < 1 for raw and Bragg data, and that W decreases upon data processing. W also gives a measure of systematic errors in the experimental data as W ≈ 1 characterizes pure Poisson data, W >> 1 is physically impossible for sufficiently large data sets of unmerged reflections and W < 1 describes the contamination with systematic errors. Systematic differences depending on the software used to process the data were found. Also, the frequency distributions in particular of σ(I) values change considerably depending on the data-processing software used. We have no explanation for these differences in the distributions of σ(I), which lead to distinct changes in the frequency distribution of the significances I/σ(I) compared with the raw data. Another consequence of Poisson statistics is that lower limits also exist for the agreement factors, the internal agreement factor and the goodness of fit. These limits depend on the moments <1/I(o)>, , and of the observed set of intensities I(o) about the origin. These agreement factors are theoretically attainable when no systematic sources of error apply. They may be used in future to construct further measures of systematic error in experimental data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introduction to the Application and Limits of Anomalous X-ray Diffraction in the Determination of Partial Structure Factors*

The use of anomalous X-ray scattering to obtain the first differences and partial structure factors normally obtained with isotopic substitution neutron diffraction is described and compared with the neutron technique. Both the problems associated with the X-ray technique and the situations in which it is highly valuable are discussed. The availability of tunable, intense synchrotron radiation ...

متن کامل

Forty Years of X-Ray Binaries

In 2012 it was forty years ago that the discovery of the first X-ray binary Centaurus X-3 became known. That same year it was discovered that apart from the High-Mass X-ray Binaries (HMXBs) there are also Low-Mass X-ray Binaries (LMXBs), and that Cygnus X-1 is most probably a black hole. By 1975 also the new class of Be/X-ray binaries was discovered. After this it took 28 years before ESAs INTE...

متن کامل

Effect of Sr substitution on structural, redox and catalytic properties of nano-particles La1-xSrxMn0.5Co0.5O3 (x = 0.0, 0.1, 0.2, 0.3, 0.4, 0.5) as a catalyst for CO oxidation

Structural features of La(1-x)SrxMn0.5Co0.5O3 (x = 0.0, 0.1, 0.2, 0.3, 0.4, and 0.5) nano-particles were investigated using X-ray powder diffraction and FT-IR spectroscopy. The characterization of compounds by X-ray powder diffraction and using Fullprof program show a cubic structure (Pm3m space group) for x = 0.0 and a rhombohedra structure (R-3c space group) for the Sr substituted La(1-x)SrxM...

متن کامل

The hydrothermal synthesis and X-ray crystal structure of Ag (1)-4, 4"-bipyridine-based coordination polymer

Hydrothermal synthetic were studied for the preparation of coordination polymeric material basedon Ag (I) and 4, 4"-bipy. A polymeric compound [Ag (4, 4'-bipy)].NO3. (I), was prepared andstructurally characterized by single crystal X-ray diffraction. Compound 1(91% yield) was isolatedfrom the reaction of AgNO3 with 4, 41bipy in 2:1 molar ratio. In compound I. each silver (I) islinked to two nit...

متن کامل

Application of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy

At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta crystallographica. Section A, Foundations of crystallography

دوره 66 Pt 6  شماره 

صفحات  -

تاریخ انتشار 2010