Detection of biological false positive syphilis serum reactions.
نویسندگان
چکیده
a lipoidal fraction, which, acting as a hapten, combines with the protein of the treponema and stimulates thl? production of antibodies (reagin) which can be measured by the so-called reagin tests. The first treponemal test using T. pallidum was introduced by Nelson and Mayer' in 1949 when they described the Treponema pallidum immobilisation test (TPI). In this test the serum of patients showing evidence of clinical immunity was able to render immobile living T. pallidum which had been obtained from primary experimental testicular lesions in rabbits. In 1957 Deacon and co-workers' introduced the fluorescein trepo~emal antibody test (FTA) as a substitute for the expensive Treponema pallidum immobilisation test. The new FTA test was very sensitive but gave some false positive results because it detected antibodies in man to the essentially non-pathogenic treponemata. Hunter et al.' absorbed the cross-reacting antibodies from the serum by treatment with Reiter's treponema, which is a cultivable, avirulent strain of Treponema. This new FTA-ABS test is more sensitive and specific for T. pallidum and enables false positive reagin reactions to be detected. We emphasise, however, that although this test is highly specific, this specificity is not absolute. Because of its ease and inexpensiveness, the FTA-ABS test is replacing the TPI test for confirmation of the presence of syphilis when the results of the reagin tests are in question.' It is also widely accepted as the standard by which false positive reactors to reagin tests for syphilis are defined. The specificity of the FTA-ABS test is influenced by the antigenic composition of T. pallidum, sharing antigens with other spirochaetes, and by cross-reacting group antibodies. Information concerning the antigenic structure of T. pallidum is incomplete. Limited studies have shown the Highly specific for diagnostic purposes, but useless for ·control of treatment. Only occasional biological false positive results. our series Not used in Excellent for control of treatment ] Diagnostically useful, but prone to bioI. false positive reactions
منابع مشابه
The biological false positive reaction to serological tests for syphilis.
Acute and chronic biological false positive reactions to serological tests for syphilis are discussed. Three cases are presented, one showing an acute and one a chronic reaction, and one in which it was not possible to determine if the reaction was acute or chronic. Once a biological false positive reaction is found, serum from the patient should be tested at intervals for at least six months t...
متن کاملChronic biological false-positive reactions to serological tests for syphilis in blood donors.
Problem sera from 375 blood donors were investigated for biological false-positive reactions to serological tests for syphilis. Problem sera are those sera in which submitting laboratories have found a reactive result to a screening test for syphilis. On each serum a cardiolipin Wassermann reaction, a Venereal Disease Research Laboratory test, a Reiter protein-complement fixation test, a Trepon...
متن کاملAgeing and false positive reactions for syphilis.
Biological false positive reactors for syphilis (BFP) are defined as those patients having reagin demonstrated by positive serological tests for syphilis and non-reactive treponemal antibody tests. Acute biological false-positive reactions (ABFP) terminate in 1 to 6 months. Patients in whom reagin persists longer than 6 months are considered to have chronic reactions (CBFP). Harvey (1962) stres...
متن کاملThe Treponema pallidum haemagglutination (TPHA) test in biological false positive and leprosy sera.
The Treponema pallidum haemagglutination (TPHA) test was carried out on 274 sera known to show biological false positive reactions to reagin tests for syphilis. The Treponema pallidum immunization (TPI) and fluorescent treponemal antibody absorption (FTA-ABS) tests were non-reactive on all these sera. Thirty-one or 11.3% showed reactive results in the TPHA test. Sera from 267 people who had lep...
متن کاملLow frequency of chronic biological false positive reactors to serological tests for syphilis in rheumatoid arthritis and ankylosing spondylitis.
In the so-called collagen diseases there is considerable overlapping of both clinical signs and serological phenomena. Elevated serum globulins, L.E.-cells, rheumatoid factors, and chronic biological false positive (CBFP) serological reactions for syphilis have been observed both in rheumatoid arthritis (RA) and in systemic lupus erythematosus (SLE). The frequency of RA among CBFPreactors has b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde
دوره 48 28 شماره
صفحات -
تاریخ انتشار 1974