Detection of Ochratoxin a Using Molecular Beacons and Real-Time PCR Thermal Cycler

نویسندگان

  • Simona Marianna Sanzani
  • Massimo Reverberi
  • Corrado Fanelli
  • Antonio Ippolito
چکیده

We developed a simple and cheap assay for quantitatively detecting ochratoxin A (OTA) in wine. A DNA aptamer available in literature was used as recognition probe in its molecular beacon form, i.e., with a fluorescence-quenching pair at the stem ends. Our aptabeacon could adopt a conformation allowing OTA binding, causing a fluorescence rise due to the increased distance between fluorophore and quencher. We used real-time PCR equipment for capturing the signal. With this assay, under optimized conditions, the entire process can be completed within 1 h. In addition, the proposed system exhibited a good selectivity for OTA against other mycotoxins (ochratoxin B and aflatoxin M1) and limited interference from aflatoxin B1 and patulin. A wide linear detection range (0.2-2000 µM) was achieved, with LOD = 13 nM, r = 0.9952, and R2 = 0.9904. The aptabeacon was also applied to detect OTA in red wine spiked with the same dilution series. A linear correlation with a LOD = 19 nM, r = 0.9843, and R2 = 0.9708 was observed, with recoveries in the range 63%-105%. Intra- and inter-day assays confirmed its reproducibility. The proposed biosensor, although still being finalized, might significantly facilitate the quantitative detection of OTA in wine samples, thus improving their quality control from a food safety perspective.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid detection of Shiga toxin-producing bacteria in feces by multiplex PCR with molecular beacons on the smart cycler.

We have developed a rapid (1-h) real-time fluorescence-based PCR assay with the Smart Cycler thermal cycler (Cepheid, Sunnyvale, Calif.) for the detection of Shiga toxin-producing Escherichia coli (STEC), as well as other Shiga toxin-producing bacteria. Based on multiple-sequence alignments, we have designed two pairs of PCR primers that efficiently amplify all variants of the Shiga toxin genes...

متن کامل

Rapid and highly sensitive detection by a real-time polymerase chain reaction using a chip coated with its reagents.

On-site detection by flow-through polymerase chain reaction (PCR) microfluidic systems for rapid and highly sensitive analysis, are significantly desired for bioanalytical and medical research. The conventional continuous-flow PCR chips realized rapid detection, but their sensitivity was very low (10(6) to 10(8) copies μL(-1)). We improved this drawback by coating the chip with a PCR reagents m...

متن کامل

Rapid quantification of microRNAs in plasma using a fast real-time PCR system.

The ability to rapidly detect circulating small RNAs, in particular microRNAs (miRNAs), would further increase their already established potential as biomarkers for a range of conditions. One rate-limiting factor in miRNA detection is the time taken to perform quantitative real-time PCR (qPCR) amplification. We therefore evaluated the ability of a novel thermal cycler to perform this step in le...

متن کامل

Using molecular beacons to detect single-nucleotide polymorphisms with real-time PCR.

Detection of single-nucleotide polymorphisms (SNPs) in high-throughput studies promises to be an expanding field of molecular medicine in the near future. Highly specific, simple, and accessible methods are needed to meet the rigorous requirements of single-nucleotide detection needed in pharmacogenomic studies, linkage analysis, and the detection of pathogens. Molecular beacons present such a ...

متن کامل

Rapid Detection of COVID-19 by RT-LAMP PCR Technique and its Comparison with Real-Time RT-PCR Method

Rapid antigen and antibody, serological tests, and RT ‑ PCR-based molecular methods are widely used for the detection of microorganisms worldwide. Objectives: This study aimed by Isothermal nucleic acid amplification techniques to detect the covid-19. Methods: In this study, 200 samples of nasopharynx and oropharynx were collected from Jamaran Heart Hospital in Tehran. Covid -19 was exami...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015