Linear Electron Accelerators for Deep X-ray Therapy
ثبت نشده
چکیده
S OF RECENT SCIENTIFIC PUBLICATIONS OF N.V. PHILIPS' GLOEILAMPENFABRIEKEN Reprints of these papers not marked with an asterisk • can be obtained free of charge upon application to Philips Electrical Ltd., Century House, Shaftesbury Avenue, London W.C.2. 2161: R. Vermeulen: Sound recording. General review, presented at the first I.C:A. Congress on Electro-accoustics, Delft, 1953 (Acustica 4, 17-21, 1954.) General considerations on sound recording. The following topics are dealt with; improvements in gramophone records, gramophone recording and reproduction, tape recorders; information, theory in relation to reproduetion of music, fidelity of the reproduction, stereophony, artificial reverberation. 2162: J. Rodrigues de Miranda: The radio set as an instrument for the reproduetion of music (Acustica 4,38-41, }954). In connection with the reproduetion of music by radio the following desiderata are put forward: 1. Distortion should be decreased. as the high frequency range increases. 2. Means are desirahle for adjusting bass response, for cutting óff and for gradual attenuation of treble, 3. The electro-acoustical engineer and the architect should cooperate closely. The cabinet must he rigid, the loudspeaker placed forward; its cloth chosen carefully. 4. The speaker should be chosen in accordance with the acoustical properties of the .cabinet, The audio-frequency characteristic of the set should' he carefully determined. 2163: W. K. Westmijze: Application of the reciprocity theorem to magnetic reproducing heads (Acustica 4,50-52, 1954). 'ill!) , It is shown that the output of a magnetic reproducing head can be calculated if the field distribution in front of the head is known for the case when the latter 'is energised, Application of this method' enables us to predict the response curve of a wideg'ap head and to explain the existing difference between wide-gap and narrow-gap measurements. 2164: A. G. Th. Becking and A. Rademakers. Noise in condenser microphones (Acustica' 4,96-98, 1954). It is pointed out that the mecha'nical resistance, used for damping a simple mechanical oscillator, acts as the source of á fluctuating force with spectral intensity 4RkT. In the case of a eondenser microphone this results in a noise pressure on the diaphragm, which lies in the region of audible sound pressures. Experimental -results, obta~ed with two microphones, agree well with th~ theory. . ' ., 2165: A. G. Th. Beckint Methods of measurement for hearing aids (Acustica 4, ~43-145, 19~4). The different ways of defining the input soillid pressure on a hearing aid are discussed. In addition, a comparison is given of thespecifications for 'acceptable hearing ai~s in s?me Europeancountries. 2166: J. Volger, J. M. Stevels and C. van Amerongen: The dielectri~ l'elaxati0!1 of glass and the pseudo-capacity of metal-to-glass interfaces, measured at extremely low frequen~ cies. (Philips Res. Rep. 8, 452-470, 1953, No.6).
منابع مشابه
Terahertz-driven linear electron acceleration
The cost, size and availability of electron accelerators are dominated by the achievable accelerating gradient. Conventional high-brightness radio-frequency accelerating structures operate with 30-50 MeV m(-1) gradients. Electron accelerators driven with optical or infrared sources have demonstrated accelerating gradients orders of magnitude above that achievable with conventional radio-frequen...
متن کاملNew Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators
Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...
متن کاملMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
متن کاملShielding simulations for safe use of curtain electron accelerator by MCNP4C
In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...
متن کاملNew electrical device for field coincidence quality control test in linear accelerators
Testing of the coincidence of a linear accelerators X-ray field and the light field as a quality control test is often done in a subjective method, involving the manual marking of pieces of film and the visual inspection of the film after irradiation. The purpose of this study was to develop an objective method for performing this test, while also increasing the accuracy, precision and the spee...
متن کاملDose Rate Influence on Deep Dose Deposition Using a 6 MV X-Ray Beam From a Linear Accelerator
Linear accelerators used in radiation therapy treatments usually provide the capability of irradiating with different dose rates. The medical physicist may choose arbitrary the dose rate to use, although the relative biological effectiveness (RBE) varies with this physical parameter. In this work the measurements of absorbed dose of the x-ray beams from a Varian 6 MV linear accelerator CLINAC 6...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014