Effect of sevoflurane anaesthesia on plasma concentrations of glutathione S-transferase.
نویسندگان
چکیده
To assess the effect of sevoflurane anaesthesia on hepatocellular integrity, we measured plasma concentrations of glutathione S-transferase (GST) before anaesthesia and 1, 3, 6 and 24 h after the end of anaesthesia in 41 healthy, Japanese patients undergoing elective, body surface surgery. Sevoflurane (approximately 1.0 MAC) was delivered in 50-66% nitrous oxide in oxygen via a circle system, with a fresh gas flow of 6 litre min-1. Ventilation was spontaneous in all patients. Mean duration of anaesthesia was 101 min. Concentrations of GST increased significantly 1 h after the end of anaesthesia (P = 0.0075), but this was not significantly different from preoperative concentrations at 3, 6 and 24 h. Three patients developed a large secondary increase in GST concentrations at 24 h. The increase observed at 1 h was probably a result of reduced total liver blood flow; the mechanism for the secondary increase at 24 h is unclear but the possibility that products of sevoflurane biotransformation are responsible cannot be excluded.
منابع مشابه
Effect of spinal anaesthesia on plasma concentrations of glutathione S-transferase.
BACKGROUND Plasma glutathione S-transferase (GST) concentration measurement is a sensitive and specific index of hepatocellular injury. GST concentration increases after anaesthesia with most volatile anaesthetic agents, but not after propofol. Such increases are thought to result from reduced liver blood flow. The effect on GST concentration of spinal (subarachnoid) anaesthesia, which might al...
متن کاملHepatocellular integrity during and after isoflurane and halothane anaesthesia in surgical patients.
Subclinical disturbance in hepatocellular integrity, indicated by glutathione transferase Alpha (GSTA), has been associated with halothane, sevoflurane and propofol, but not with isoflurane anaesthesia. We anaesthetized 82 patients with isoflurane or halothane at 1 MAC for superficial surgery. GSTA concentration were measured with a sensitive time-resolved immunofluorometric assay in serum samp...
متن کاملHepatic function and indocyanine green clearance during and after prolonged anaesthesia with propofol.
We have studied the effects of propofol on hepatic function and clearance of indocyanine green (ICG) in 13 consecutive patients undergoing prolonged plastic and reconstructive surgery. Hepatic function was assessed using serum concentrations of liver-specific glutathione-S-transferase (GST). There were no significant changes in GST activity or plasma clearance of ICG throughout the study.
متن کاملIndocyanine green clearance and hepatic function during and after prolonged anaesthesia: comparison of halothane with isoflurane.
Specific biochemical and physiological tests of liver function were used to assess 20 consecutive patients undergoing prolonged head and neck surgery with halothane or isoflurane anaesthesia. Hepatic function was assessed by measurement of serum concentrations of total bilirubin and albumin, and plasma activity of pseudocholinesterase, gamma-glutamyl transferase (GGT), aspartate transaminase (A...
متن کاملSevoflurane anaesthesia causes a transient decrease in aquaporin-2 and impairment of urine concentration.
Sevoflurane anaesthesia is occasionally associated with polyuria, but the exact mechanism of this phenomenon has not been clarified. Aquaporin-2 (AQP2) is an arginine vasopressin (AVP)-regulated water channel protein localized to the apical region of renal collecting duct cells and is involved in the regulation of water permeability. To elucidate the effect of sevoflurane anaesthesia on urine c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 77 3 شماره
صفحات -