Determination of trace amounts of bromide by flow injection/stopped-flow detection technique using kinetic-spectrophotometric method.

نویسندگان

  • K Uraisin
  • D Nacapricha
  • S Lapanantnoppakhun
  • K Grudpan
  • S Motomizu
چکیده

A simple, sensitive and selective method for the determination of bromide in seawater by using a flow injection/stopped-flow detection technique was examined. The detection system was developed for a new kinetic-spectrophotometric determination of bromide in the presence of chloride matrix without any extraction and/or separation. The detection was based on the kinetic effect of bromide on the oxidation of methylene blue (MB) with hydrogen peroxide in a strongly acidic solution. Large amounts of chloride could enhance the sensitivity of the method as an activator. The decolorisation of the blue color of MB was used for the spectrophotometric determination of bromide at 746nm. A stopped-flow approach was used to improve the sensitivity of the measurement and provide good linearity of the calibration over the range of 0-3.2mugml(-1) of bromide. The relative standard deviation was 0.74% for the determination of 2.4mugml(-1) bromide (n=5). The detection limit (3sigma) was 0.1mugml(-1) with a sampling frequency of 12h(-1). The influence of potential interfering ions was studied. The proposed method was applied to the determination of bromide in seawater samples and provided satisfactory results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis

Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...

متن کامل

Kinetic spectrophotometric determination of trace amounts of nitrite ion using potassium bromate-murexide mixture in acidic media

A new, simple, rapid, and cheap method for determination of trace amounts of nitrite ion is reported.Determination is based on reduction of bromate ion by nitrite ion, in the presence of murexide inacidic media. During reaction of bromate ion with nitrite ion, the reaction mixture is decolorized.The absorbance changes is then monitored spectrophotometricaly at 520 nm, at 25 °C. Dynamicrange of ...

متن کامل

Kinetic-spectrophotometric method for the determination of trace amounts of bromide in seawater.

A novel simple, sensitive and rapid kinetic-spectrophotometric method is proposed for the determination of trace amounts of bromide. The method is based on its catalytic effect on the oxidation of methylene blue (MB) by hydrogen peroxide in strongly acidic solution. The oxidation reaction is activated by large amounts of chloride and can be monitored spectrophotometrically by measuring the decr...

متن کامل

KINETIC-SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF NITRITE BY THE REACTION OF METHYL ORANGE FORMATION

The composite diazotization coupling reaction of sulfanilic acid and N, Ndimethylaniline was used for the precise, accurate, and rapid determination of trace amounts of nitrite ion (0.02-3 µg/ml). The reaction was monitored spectrophotometrically by measuring the absorbance of the produced methyl orange at 510 nm by a fixed the method of 5.0 minutes. The relative standard deviation for the...

متن کامل

Kinetic Spectrophotometric Method for Trace Amounts Determination of Bromide in Pharmaceutical Samples Using Janus Green-Bromate System

A new simple and rapid kinetic spectrophotometric method has been developed to trace amounts determination of bromide. This method is based on the catalytic effect of bromide on the reaction between Janus Green and bromate in sulfuric acid media. The reaction was followed spectrophotometrically by measuring the absorbance at 618 nm. The fixedtime method was used for the first 210 s. The influen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 2005