A robust and accurate surrogate method for monitoring the frequency and duration of combined sewer overflows

نویسندگان

  • Thomas Hofer
  • Albert Montserrat
  • Guenter Gruber
  • Valentin Gamerith
  • Lluis Corominas
  • Dirk Muschalla
چکیده

Discharges of untreated wastewater from combined sewer overflows (CSOs) can affect hydraulic stress and have significant environmental impacts on receiving water bodies. Common flow rate and water level sensors for monitoring of CSO events are expensive in terms of investment costs, installation, operation and maintenance. This paper presents a novel surrogate method to detect CSO events by using two low-cost temperature sensors. The novelty is the experimental setup for installation of temperature sensors in CSO structures and an algorithm developed to automatically calculate the duration of CSO events considering the response time of the system. The occurrence and duration of CSO events is computed based on the convergence of the two temperature signals. The method was tested under field conditions in a CSO structure, and the results were compared to the information gathered from a parallel installed flow sensor. The application of two temperature sensors installed inside a CSO structure was proven to be robust and accurate for the automatic detection of the occurrence and duration of CSO events. Within the 7-month test phase, 100% of the 20 CSO events could be detected without false detections. The accuracy of detecting the start and end of the CSO events was 2 min in comparison to the flow sensor.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bacterial diversity impacts as a result of combined sewer overflow in a polluted waterway

Newtown Creek is an industrial waterway and former tidal wetland in New York City. It is one of the most polluted water bodies in the United States and was designated as a superfund site in 2010. For over a century, organic compounds, heavy metals, and other forms of industrial pollution have disrupted the creek’s environment. The creek is also impacted by discharges from twenty combined sewer ...

متن کامل

Removal of nutrients from combined sewer overflows and lake water in a vertical-flow constructed wetland system.

Lake Utterslev is situated in a densely built-up area of Copenhagen, and is heavily eutrophicated from combined sewer overflows. At the same time the lake suffers from lack of water. Therefore, a 5,000 m2 vertical flow wetland system was constructed in 1998 to reduce the phosphorus discharge from combined sewer overflows without reducing the water supply to the lake. During dry periods the cons...

متن کامل

Monitoring of β-D-Galactosidase Activity as a Surrogate Parameter for Rapid Detection of Sewage Contamination in Urban Recreational Water

Simple, automated methods are required for rapid detection of wastewater contamination in urban recreational water. The activity of the enzyme β-D-galactosidase (GAL) can rapidly (<2 h) be measured by field instruments, or a fully automated instrument, and was evaluated as a potential surrogate parameter for estimating the level of fecal contamination in urban waters. The GAL-activity in rivers...

متن کامل

Dynamics of rain-induced pollutographs of solubles in sewers.

When looking at acute receiving water impacts due to combined sewer overflows the characteristics of the background diurnal sewage flux variation may influence the peak loads from combined sewer overflows (CSO) and wastewater treatment plant (WWTP) effluent significantly. In this paper, effects on the dynamic compounds transported in the sewer, on CSO discharges and WWTP loading are evaluated b...

متن کامل

Combined Sewer Overflow Technology Fact Sheet Maximization of In-line Storage

Sewer systems that convey both sanitary sewage and storm water through a single pipe are referred to as combined sewer systems (CSSs). In dry weather, the CSS is able to convey all flows to the wastewater treatment facility. During periods of heavy rainfall, however, the capacity of the CSS may be exceeded and an untreated combination of sewage and storm water may discharged directly into a nea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 190  شماره 

صفحات  -

تاریخ انتشار 2018