Clinical validity of measuring time difference between onset of mitral inflow and onset of early diastolic mitral annulus velocity in the evaluation of left ventricular diastolic function.

نویسندگان

  • Dae-Won Sohn
  • Young-Jin Kim
  • Young-Bae Park
  • Yun-Shik Choi
چکیده

OBJECTIVES This study was performed to validate the clinical usefulness of measuring the time difference between onset of mitral inflow and onset of early diastolic mitral annulus velocity (T(E'-E)) for the evaluation of left ventricular (LV) diastolic function. BACKGROUND In recent studies, T(E'-E) correlated well with the time constant of LV pressure decay (tau), and the ratio of IVRT/T(E'-E), where IVRT is isovolumic relaxation time, was useful in the prediction of elevated LV filling pressure. METHODS Simultaneous left heart catheterization and Doppler echocardiography were performed in 40 patients. RESULTS The T(E'-E) was evaluated in the same cardiac cycle and in the same hemodynamic status in 31 patients. Despite the wide range of tau (31 to 70 ms), there was no delay in the onset of mitral annulus velocity compared with the onset of mitral inflow (T(E'-E) = 0) in 27 patients and, therefore, T(E'-E) did not correlate with tau. Only three patients showed prolongation in T(E'-E), and all three showed tau >or=50 ms and pre-A-wave pressure >or=18 mm Hg. In one patient, mitral annulus velocity began earlier than the onset of mitral inflow. Because T(E'-E) was 0 in the majority of patients, the LV filling pressure could not be predicted by the previously suggested index of IVRT/T(E'-E.) CONCLUSIONS In contrast to previous studies, T(E'-E) did not correlate with tau, and IVRT/ T(E'-E) could not be applied in the prediction of filling pressure, because of the limitation of a zero denominator. However, prolongation of T(E'-E) might suggest an elevated filling pressure in the setting of prolonged tau.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Subclinical Myocardial Changes in Non-Alcoholic Fatty Liver Disease: A Case-Control Study Using Speckle Tracking Echocardiography

Background: Considering the association between cardiac abnormalities and non-alcoholic fatty liver disease (NAFLD), the present study aimed to evaluate the relationship between biopsy-proven NAFLD and functional echocardiographic parameters, including left ventricular (LV) global longitudinal strain (GLS) in asymptomatic individuals. Methods: Thirty asymptomatic patients with liver biopsy-prov...

متن کامل

توانایی اکوکاردیوگرافی داپلر در تخمین فشار پرشدگی بطن چپ در تنگی دریچه میترال

Background: Estimation of Left Ventricular End Diastolic Pressure (LVEDP) among patients with Mitral Stenosis (MS) helps to diagnose diastolic dysfunction and to explain their symptoms. However, Conventional Doppler measurements have limitation in predicting of LVEDP. This study sought to establish whether the correlation between measurements derived from Tissue Doppler echocardiography and LVE...

متن کامل

Echocardiographic left ventricular functional changes in acute hypothyroidism vs. subclinical hyperthyroidism in patients with differentiated thyroid carcinoma

Introduction:  In order to assess echocardiographic left ventricular functional indices in patients with differentiated thyroid carcinoma (DTC), after L-T4 withdrawal (short-term overt hypothyroidism) and during TSH suppressive therapy, we have evaluated cardiac hemodynamics in a single cohort study. Methods: 24 patients with DTC were studied in two phases: 1: at least 4 weeks after L-T4 withd...

متن کامل

Evaluation of the Effect of Elective Percutaneous Coronary Intervention as a Treatment Method on the Left Ventricular Diastolic Dysfunction in Patients with Coronary Artery Disease

BACKGROUND Although percutaneous coronary intervention (PCI) is an excellent therapy for coronary artery disease, there is a paucity of information on the efficacy of PCI in improving diastolic function, especially in Iran. Because of the high prevalence of left diastolic dysfunction in coronary artery disease patients and its probable progression to heart failure, an evaluation of the role of ...

متن کامل

Cardiac MRI correlates of diastolic left ventricular function assessment by echocardiography

Background Transthoracic echocardiography (TTE) provides noninvasive measures of diastolic left ventricular (LV) function by assessing mitral inflow and mitral annular motion. Given the excellent spatial and temporal resolution of CMR, we developed a novel method to calculate several correlative measures of diastolic and systolic LV function. The maximum velocity of the atrioventricular junctio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 43 11  شماره 

صفحات  -

تاریخ انتشار 2004