[Comparison of dynamic contour tonometry, Goldmann and pneumotonometer in ocular hypertension patients and their relationship to pachymetry and ocular pulse amplitude].

نویسندگان

  • T Colás-Tomás
  • M Prieto-Del Cura
  • I Villafruela-Güemes
  • A Clariana-Martín
  • A Valdivia-Pérez
چکیده

PURPOSE To determine the relationship between dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT) and pneumotonometry (PNT) in ocular hypertension patients (OHT) and their relationship to central corneal thickness (CCT) and ocular pulse amplitude (OPA). METHODS Sixty patients (101 eyes) with intraocular pressure (IOP) ≥21 mmHg using GAT and normal appearing optic nerve heads and normal visual fields were included. The following tests were performed simultaneously during a single visit: IOP using DCT, GAT and PNT, OPA using DCT and CCT using ultrasound pachymetry. We studied the difference IOP between these 3 tonometers using Wilcoxon non-parametric test and the effect of CCT on IOP and OPA, as well as the relationship between OPA and IOP using Spearman correlation coefficient. RESULTS The median PNT IOP was 24 mmHg (Inter-quartile range [IQR]: 22-26), median GAT IOP was 22 mmHg (IQR: 22-24), and median DCT IOP was 28.2 mmHg (IQR: 24.1-30.7). PNT and DCT had higher IOP values than GAT (median 2 mmHg and 6.2 mmHg, respectively). Mean CCT was 594.5 μm (SD 30.0). GAT IOP and DCT IOP showed an increase with increased corneal thickness (r:0.209; P=.036 and r:0.195; P=.051, respectively). PNT IOP did not change with CCT (r:0.15; P=.12). The median OPA was 4.8 mmHg (IQR: 3.6-6.1), and significantly increased with GAT IOP (r:0,38; P<.001) and with CCT (r:0.287; P=.004). This association was unclear with IOP PNT and IOP DCT (r:0.067; P=.50 and r:0,17, P=.08, respectively). CONCLUSIONS DCT and PNT IOP values were higher than GAT IOP measurements in ocular hypertension patients. GAT IOP showed a significant increase with increased corneal thickness. Increased OPA seems to correlate with increased CCT and IOP, particularly if GAT is used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes

BACKGROUND The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure...

متن کامل

Comparing dynamic contour tonometry to Goldmann and hand-held tonometry in normal, ocular hypertension, and glaucoma populations.

We prospectively compared dynamic contour tonometry (DCT) to Goldmann (GAT) and hand-held tonometry (HHT) in normal, ocular hypertension, and glaucoma populations. Both measurements were made on each patient within a 5-minute period during routine office exams over 4 months. While DCT is in good overall agreement with GAT and HTT, there is some systematic deviation at different pressure ranges ...

متن کامل

Review on Dynamic Contour Tonometry and Ocular Pulse Amplitude.

Intraocular pressure (IOP) measurement is the cornerstone of the management of glaucoma patients. The gold standard for assessing IOP is Goldmann applanation tonometry (GAT). Recently, the dynamic contour tonometer (DCT) has become available. While both devices provide reliable IOP measurements, the results are not interchangeable. DCT has the advantage of measuring an additional parameter: ocu...

متن کامل

Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?

We demonstrate the close relationship between a conspicuous ocular pulse amplitude and severe underlying cardiovascular disease. Two otherwise symptom-free glaucoma patients without any previously diagnosed underlying cardiovascular pathology but with a conspicuous ocular pulse amplitude and who underwent routine examinations in our glaucoma department were referred to the appropriate specialty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de la Sociedad Espanola de Oftalmologia

دوره 87 12  شماره 

صفحات  -

تاریخ انتشار 2012