Measurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible
نویسندگان
چکیده
Background. There is no doubt that the success of the dental implants depends on the stability. The aim of this work was to measure the stability of dental implants prior to loading the implants, using a resonance frequency analysis (RFA) by Osstell mentor device. Methods. Ten healthy and nonsmoker patients over 40 years of age with at least six months of complete or partial edentulous mouth received screw-type dental implants by a 1-stage procedure. RFA measurements were obtained at surgery and 1, 2, 3, 4, 5, 7, and 11 weeks after the implant surgery. Results. Among fifteen implants, the lowest mean stability measurement was for the 4th week after surgery in all bone types. At placement, the mean ISQ obtained with the magnetic device was 77.2 with 95% confidence interval (CI) = 2.49, and then it decreased until the 4th week to 72.13 (95% CI = 2.88), and at the last measurement, the mean implant stability significantly (P value <0.05) increased and recorded higher values to 75.6 (95% CI = 1.88), at the 11th week. Conclusions. The results may be indicative of a period of time when loading might be disadvantageous prior to the 4th week following implant placement. These suggestions need to be further assessed through future studies.
منابع مشابه
Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملImmediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملResonance frequency analysis of dental implant stability during the healing period.
PURPOSE The objective of the present study was to measure the implant stability quotient (ISQ) values during the osseointegration period, and determine the factors that affect implant stability. MATERIALS AND METHODS To measure implant stability, resonance frequency analysis (RFA) was performed in 24 patients (12 women, 12 men) with a total 64 Defcon implants (10 anterior maxilla, 12 posterio...
متن کاملResonance frequency analysis after the placement of 133 dental implants.
INTRODUCTION The primary stability of dental implants is related to the bone in contact with the latter, and can be evaluated by resonance frequency analysis. MATERIAL AND METHODS Measurements were made in 133 implants (62 in the upper jaw and 71 in the mandible) of resonance frequency and insertion force to determine implant stability on the day of surgery, with an evaluation of its relation...
متن کاملPredictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.
BACKGROUND Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. PATIENTS AND METHODS Seventy patients with complete mandibular edentulism underwent ...