Determination of glyphosate in water samples by alternating-current oscillopolarographic titration.
نویسندگان
چکیده
This paper describes a novel, simple and sensitive method for the determination of glyphosate in water samples by alternating-current oscillopolarographic titration. Under an acidic condition, glyphosate can be transferred into a nitrosocompound by reacting with NaNO2. The titration end-point was obtained by the formation of a sharp cut in the oscillopolarographic with infinitesimal NaNO2 on double platinum electrodes. The results showed that glyphosate had an excellent linear relationship over the range of 7.16 x 10(-6) - 4.14 x 10(-3) mol L(-1), the RSD of the proposed method was lower than 3%, and the spiked recoveries of three real water samples were in the range of 97.7 - 100.2%.
منابع مشابه
Rapid determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration.
A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol could be transferred into a nitroso-compound by reacting with NaNO2. The titration end-point was obtained by the formation of a sharp cut in the oscillopolarographic with infinitesimal...
متن کاملDetermination of glyphosate in water samples by multi-pumping flow system coupled to a liquid waveguide capillary cell.
A simple screening method was developed for the determination of glyphosate in water samples using a multi-pumping flow system. The proposed method is based on the reaction between glyphosate and p-dimethylaminocinnamaldehyde (p-DAC), in an acid medium where the reaction product can be measured spectrophotometrically at λ(max) = 495 nm. An experimental design methodology was used to optimize ...
متن کاملSimple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples
The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a...
متن کاملAutomated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides
Glyphosate and glufosinate are widely used herbicides and, thus, there is an interest in the reliable and sensitive determination of glyphosate in water and food. These pesticides are diffi cult to extract and analyze because of their high polarity. In this report, we describe an automated workfl ow for the FMOC-derivatization, sample cleanup, and LC/MS/MS analysis using a GERSTEL MultiPurpose ...
متن کاملTime-integrated sampling of glyphosate in natural waters.
Environmental monitoring of pesticide residues in surface water is often done with time-integrated sampling where a specified volume is sampled each hour during, e.g., a week, thus avoiding at momentary high or low extreme concentrations. However, sampling over an extended period of time can result in losses of easily degradable analytes, why the stability of the target analytes over the timesp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 10 شماره
صفحات -
تاریخ انتشار 2004