Aortic input impedance in infants and children.
نویسندگان
چکیده
Flow and pressure measurements were performed in the ascending aortas of six pediatric patients ranging in age from 1 to 4 yr and in weight from 7.2 to 16.4 kg. From these measurements, input impedance was calculated. It was found that total vascular resistance decreased with increasing patient weight and was approximately one to three times higher than those of adults. Conductance per unit weight was relatively constant but was approximately three times higher than for adults. Strong inertial character was observed in the impedance of four of the six patients. Among a three-element and two four-element lumped-parameter models, the model with characteristic aortic resistor (R(c)) and inertance in series followed by parallel peripheral resistor (R(p)) and compliance fitted the data best. R(p) decreased with increasing patient weight and was one to three times higher than in adults, and R(c) decreased with increasing patient weight and was 2 to 15 times higher. The R(p)-to-R(c) ratio differed significantly between infants and children vs. adults. The results suggested that R(p) developed more rapidly with patient weight than did R(c). Compliance values increased with increasing patient weight and were 3 to 16 times lower than adult values.
منابع مشابه
Aortic input impedance increases with age in healthy men and women.
Aortic input impedance represents the hydraulic load presented by the systemic circulation to the left ventricle of the heart and is increased in patients with cardiovascular disease. Aging is a strong independent risk factor for cardiovascular disease and could exert this effect partly through an increase in modulus of aortic input impedance. We used a novel noninvasive technique to determine ...
متن کاملAssessment of Windkessel as a model of aortic input impedance.
To facilitate the analysis of aortic-ventricular coupling, simplified models of aortic input properties have been developed, such as the three-element Windkessel. Even though the impedance spectrum of the Windkessel reproduces the gross features of the real aortic input impedance, it fails to reproduce many of its details. In the present study we assessed the physiological significance of the d...
متن کاملSimulation of adaptation of blood vessel geometry to flow and pressure: Implications for arterio-venous impedance
Aortic input impedance relates pressure to flow at the aortic entrance distal to the aortic valve. We designed the CircAdapt three-element model of this impedance, consisting of resistive wave impedance, arterial compliance and peripheral resistance. Direct association of the elements with physical properties facilitated incorporation of nonlinear elastic properties of wall material and adaptat...
متن کاملAortic input impedance in heart failure.
The input impedance of the systemic circulation was calculated from recordings of pulsatile pressure and flow in the ascending aorta of 20 patients. Ten patients had clinical and hemodynamic evidence of heart failure. The other 10 subjects had no clinical evidence of heart failure and were used as a control group. In the heart failure patients, both input resistance and characteristic impedance...
متن کاملManipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance.
Dramatic changes in the shape of pulsatile ascending aortic pressure and flow wave forms occur during the Valsalva maneuver in man. To study these changes, aortic pressure and flow signals were recorded in eight patients using a multisensor catheter. Aortic input impedance was derived during the control, strain and postrelease phases of the Valsalva maneuver. During control, well-defined minima...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 88 6 شماره
صفحات -
تاریخ انتشار 2000