The Effect of Axial Load in the Tibia on the Response of the 90 degrees Flexed Knee to Blunt Impacts with a Deformable Interface.

نویسندگان

  • Eric G Meyer
  • Michael T Sinnott
  • Roger C Haut
  • Gopal S Jayaraman
  • Walter E Smith
چکیده

Lower extremity injuries are a frequent outcome of automotive accidents. While the lower extremity injury criterion is based on fracture of bone, most injuries are of less severity. Recent studies suggest microscopic, occult fractures that have been shown to be precursors of gross bone fractures, may occur in the kneecap (patella) for impacts with rigid and deformable interfaces due to excessive levels of patello-femoral contact pressure. One method of reducing this contact pressure for a 90 degrees flexed knee is to provide a parallel pathway for knee impact loads into the tibial tuberosity. Yet, blunt loads onto the tibial tuberosity can cause posterior drawer motion of the tibia, leading to injury or rupture of the posterior cruciate ligament (PCL). Recently studies have shown that axial loads in the tibia, which are measured during blunt loading on the knee in typical automobile crashes, can induce anterior drawer motion of the tibia and possibly help unload the PCL. The purpose of the current study was to explore the effect of combined anterior knee loading (AKL) and axial tibia loading (ATL), on response and injury for the 90 degrees flexed human knee. In repeated impacts with increasing ATL the stiffness of the knee to an AKL impact increased. For a 3 kN AKL, the stiffness of the knee increased approximately 26% when the ATL was increased from 0 kN to 2 kN. For 6 kN and 9 kN AKL, the stiffness was increased approximately 17% and 20%, respectively, when the ATL was increased from 0 kN (uniaxial) to 4 kN (biaxial). The effect, however, was not statistically significant at the 9 kN AKL level. The posterior tibial drawer was shown to increase with increased AKL and decrease with increased levels of ATL at an average of 0.3 mm per kN ATL for both the 3 kN and 6 kN ATL scenarios. For 9 kN AKL this drawer displacement was significantly reduced for biaxial versus uniaxial impacts, from 7.4+/-1.4 mm to 5.8+/-0.6 mm, respectively. Additionally, the percentage of the load carried by the tibial tuberosity increased with an ATL. For AKL impacts of 3, 6, and 9 kN, the percentage of load carried by the tibial tuberosity increased from 2.1% (range 0-19%) to 4.9% (0-36%), 2.1% (0-15%) to 6.9% (0-36%), and 8.7% (0-25%) to 12.7% (0-33%), respectively, between uniaxial and biaxial tests. The biaxial loading scenario also resulted in a reduction of the patello-femoral (PF) contact force as the ATL was increased. Ten knee impacts resulted in PCL tears at an average peak load of 12.7+/-2.4 kN in biaxial impacts (n=5) and 12.0+/-3.1 kN for uniaxial impacts (n=5). These PCL injured specimens had an average age of 62+/-11.3 years. The remaining specimens (n=11, 78+/-12.9 years of age) had bone fractures at approximately 8.9+/-3.1 kN. This study showed that combinations of compressive ATL and AKL reduced the PF contact force and had a stiffening effect on the response of the knee impacting a stiff but deformable interface. Furthermore, ATL reduced the posterior drawer of the tibia, which is the current basis for PCL injury in the knee, although it did not reduce the incidence of PCL injury in this study. While the current injury tolerance criterion reflects the vulnerability of the PCL to injury by limiting tibial drawer to 15 mm, the current dummy design does not incorporate the stiffening effect of an ATL that may occur at the same time as knee contact with an instrument panel during a typical automotive crash.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

راستای اندام تحتانی در بزرگسالان

  Background & Aim: Normal axial alignment restoration in lower extremities is very important for surgeons that perform reconstructive surgeries. Since normal values of axial alignment in Iranian population aren't available, normal values in western countries are used in practice.   In this study axial alignment norms in Iranian adults were determined and the results were compared with those of...

متن کامل

بررسی شکستگیهای جوش نخورده تیبیا با استفاده از کونچر بعد از ریم کردن کانال داخل استخوان

 Non-:::union::: is a complication in the management of patients who have a fracture of the tibia. The records of twenty patients who were treated by intramedullary nailing with reaming for non :::union::: of the tibia were reviewed.   The fractures had been treated initially by closed reduction and immobilization in a cast, external fixation, fixation by pins in a plaster cast and dynamic comp...

متن کامل

An Analytical Solution on Size Dependent Longitudinal Dynamic Response of SWCNT Under Axial Moving Harmonic Load

The main purposes of the present work are devoted to the investigation of the free axial vibration, as well as the time-dependent and forced axial vibration of a SWCNT subjected to a moving load. The governing equation is derived through using Hamilton's principle. Eringen’s nonlocal elasticity theory has been utilized to analyze the nonlocal behaviors of SWCNT. A Galerkin method based on a clo...

متن کامل

Deflection of a hyperbolic shear deformable microbeam under a concentrated load

Deflection analysis of a simply supported microbeam subjected to a concentrated load at the middle is investigated on the basis of a shear deformable beam theory and non-classical theory. Effects of shear deformation and small size are taken into consideration by hyperbolic shear deformable beam theory and modified strain gradient theory, respectively. The governing differential equations and c...

متن کامل

Polyethylene contact stresses, articular congruity, and knee alignment.

Increased conformity at the tibiofemoral articulation increases contact area and reduces contact stresses in total knee arthroplasty. Malalignment, however, can increase polyethylene contact stresses. The effect of knee alignment and articular conformity on contact stresses was evaluated in a finite element model. The polyethylene insert and femoral component were modeled in high- and low-confo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stapp car crash journal

دوره 48  شماره 

صفحات  -

تاریخ انتشار 2004