Measurement of tumor oxygenation: a comparison between polarographic needle electrodes and a time-resolved luminescence-based optical sensor.

نویسندگان

  • D R Collingridge
  • W K Young
  • B Vojnovic
  • P Wardman
  • E M Lynch
  • S A Hill
  • D J Chaplin
چکیده

A novel oxygen sensor which does not rely on electrochemical reduction has been used to measure the oxygenation of the murine sarcoma F in a comparative study with an existing polarographic electrode that is available commercially. The prototype luminescence sensor yielded an oxygen distribution comparable with readings made using a pO2 histograph. The percentage of regions detected that had a pO2 less than 5 mm Hg was 79 and 75 using the Eppendorf pO2 histograph and the luminescence fiber optic sensor, respectively. These values were compatible with a measured radiobiologically hypoxic fraction of 67% in this tumor. The polarographic method detected more regions with a pO2 of 2.5 mm Hg or less (69%) compared with the optical sensor (50%) (P < 0.05). This could reflect differences in the oxygen use of the sensing devices. This initial assessment indicates the potential of a fiber-optic-based oxygen-monitoring system. Such a system should have several advantages including monitoring temporal oxygen changes in a given microregion and use with NMR procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of tumor oxygenation: in vivo comparison of a luminescence fiber-optic sensor and a polarographic electrode in the p22 tumor.

Hypoxia is important in tumor biology and therapy. This study compared the novel luminescence fiber-optic OxyLite sensor with the Eppendorf polarographic electrode in measuring tumor oxygenation. Using the relatively well-oxygenated P22 tumor, oxygen measurements were made with both instruments in the same individual tumors. In 24 air-breathing animals, pooled electrode pO(2) readings lay in a ...

متن کامل

Optical sensor-based oxygen tension measurements correspond with hypoxia marker binding in three human tumor xenograft lines.

Hypoxia has a negative effect on the outcome of radiotherapy and surgery and is also related to an increased incidence of distant metastasis. In this study, tumor pO(2) measurements using a newly developed time-resolved luminescence-based optical sensor (OxyLitetrade mark) were compared with bioreductive hypoxia marker binding (pimonidazole). Single pO(2) measurements per tumor were compared to...

متن کامل

First experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors

Background. The purpose of this preliminary study was to evaluate a novel luminescence-based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen (pO2) in tumors and for the detection of changes in pO2 as a function of time. The new method was used simultaneously with the laser Doppler flowmetry method for the measurement of relative tissue perfusion. Materials ...

متن کامل

Oxygenation and blood flow in tumors treated with hydralazine: evaluation with a novel luminescence-based fiber-optic sensor.

Two optical methods were used simultaneously to evaluate the effect of a vasoactive drug hydralazine on oxygenation and blood flow in SA-1 tumors in A/J mice. A novel luminescence-based optical sensor (OxyLite instrument, Oxford Optronix, UK) was used to monitor partial pressure of oxygen (pO2) in tumors. Laser Doppler flowmetry was used to assess relative blood perfusion in tumors. Measurement...

متن کامل

Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique

INTRODUCTION AND METHODS Dynamic fluorescence quenching is a technique that may overcome some of the limitations associated with measurement of tissue partial oxygen tension (PO2). We compared this technique with a polarographic Eppendorf needle electrode method using a saline tonometer in which the PO2 could be controlled. We also tested the fluorescence quenching system in a rodent model of s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiation research

دوره 147 3  شماره 

صفحات  -

تاریخ انتشار 1997