Exact Interior Reconstruction from Truncated Limited-Angle Projection Data

نویسندگان

  • Yangbo Ye
  • Hengyong Yu
  • Ge Wang
چکیده

Using filtered backprojection (FBP) and an analytic continuation approach, we prove that exact interior reconstruction is possible and unique from truncated limited-angle projection data, if we assume a prior knowledge on a subregion or subvolume within an object to be reconstructed. Our results show that (i) the interior region-of-interest (ROI) problem and interior volume-of-interest (VOI) problem can be exactly reconstructed from a limited-angle scan of the ROI/VOI and a 180 degree PI-scan of the subregion or subvolume and (ii) the whole object function can be exactly reconstructed from nontruncated projections from a limited-angle scan. These results improve the classical theory of Hamaker et al. (1980).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interior SPECT- Exact and Stable ROI Reconstruction from Uniformly Attenuated Local Projections.

Single photon emission computed tomography (SPECT) is an important biomedical imaging modality. However, since gamma cameras are expensive and bulky, truncated projection data are either preferred or unavoidable. Inspired by the recent results on interior tomography in the x-ray CT field, here we present the interior SPECT approach for exact and stable reconstruction of a region of interest (RO...

متن کامل

Piecewise-Constant-Model-Based Interior Tomography Applied to Dentin Tubules

Dentin is a hierarchically structured biomineralized composite material, and dentin's tubules are difficult to study in situ. Nano-CT provides the requisite resolution, but the field of view typically contains only a few tubules. Using a plate-like specimen allows reconstruction of a volume containing specific tubules from a number of truncated projections typically collected over an angular ra...

متن کامل

Two-dimensional iterative region-of-interest (ROI) reconstruction from truncated projection data.

A small detector or limited gantry rotation angles may cause data truncation, in which case the entire object cannot be completely reconstructed. However, a small region of interest (ROI) may be recoverable in certain truncation situations. Two analytical methods have been proposed for exact ROI reconstruction. Here we evaluate the capability of ROI reconstruction using an maximum-likelihood ex...

متن کامل

Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.

In this paper, we present a new algorithm designed for a specific data truncation problem in fan-beam CT. We consider a scanning configuration in which the fan-beam projection data are acquired from an asymmetrically positioned half-sized detector. Namely, the asymmetric detector only covers one half of the scanning field of view. Thus, the acquired fan-beam projection data are truncated at eve...

متن کامل

3D Image Reconstruction from Truncated Helical Cone Beam Projection Data - A Linear Prediction Approach

With the introduction of 2D flat-panel X-ray detectors, 3D image reconstruction using helical cone-beam tomography is fast replacing the conventional 2D reconstruction techniques. In 3D image reconstruction, the source orbit or scanning geometry should satisfy the data sufficiency or completeness condition for exact reconstruction. The helical scan geometry satisfies this condition and hence ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International Journal of Biomedical Imaging

دوره 2008  شماره 

صفحات  -

تاریخ انتشار 2008